Filter Mats; Control - Rittal 3237 Series Installation Manual

Fan-and-filter unit
Hide thumbs Also See for 3237 Series:
Table of Contents

Advertisement

3 Device descripti
3 1 2 C
tr
E
Rittal fan-and-filter units may be controlled
more efficiently using a thermostat
(Model No. 3110.000), digital temperature
display (Model No. 3114.200),
temperature-dependent speed control
(Model No. 3120.200, 3235.440, 3235.450)
and/or hygrostat (Model No. 3118.000).
The control unit 3120.200 can
only be used with single-phase
AC units. The control units
3235.440 and 3235.450 can
only be used with fan-and-filter
units with integrated control
interface (EC fan-and-filter units
and fan-and-filter units with
EMC shielding from an air
throughput of 180 m
Model No. 3240.500/600,
3241.500/600, 3243.500/600,
3244.500/600, 3245.500/600.
3 1 3 Safety equip e t
The fan is equipped with thermal winding
protection devices for protection against
excess current and, in some cases,
against overtemperature. For rotary current
fans, the winding protection is located in
the star earthing of the motor.
3 1 4 Fi ter
The fan-and-filter unit/outlet filter is sup-
plied with a standard filter mat already in-
stalled. The filter must be checked regular-
ly in accordance with the level of dust
exposure and replaced as necessary.
In order to increase the protection catego-
ry, and in the case of dust with a grain size
of < 10 µm, we recommend the use of fine

filter mats.

The air throughput volume will
be reduced.
Special filter mats are required
for EMC fan-and-filter units
(see accessories).
6
te
3
/h.
ats
te
Rittal fan-and-filter unit assembly and operating instructions
3.2 Proper use
Rittal fan-and-filter units were developed
and designed in accordance with the state
of the art and the recognised rules govern-
ing technical safety. Nevertheless, if used
improperly, they may pose a threat to life
and limb or cause damage to property.
The unit is only intended for ventilating en-
closures and electronic cases. Any other
use is deemed improper. The manufactur-
er will not be liable for any damages
caused as a result of improper use, or for
incorrect assembly, installation and use.
All risk is borne solely by the user.
Proper usage also includes the observa-
tion of all valid documents and compli-
ance with the inspection and servicing
conditions.
3.3 Scope of supply
The fan is supplied in a packaging unit
in a fully assembled state and ready to
connect.
Please check the scope of supply for
completeness.
Qty
Descripti
1
Fan-and-filter unit
4
– Mounting screws (not for
3237.1xx to 3239.1xx)
1
– Assembly, installation and
operating instructions
1
Drilling template, self-adhesive
1
Standard or EMC filter mat
Tab. 1:
Scope of supply