List Of Router Parameters; List Of Ra Router-Actuator Parameters; Installation Notes - Carel BP SE Sensor User Manual

Carel wireless sensors for monitoring environmental conditions - temperature, humidity, light
Table of Contents

Advertisement

ENG

10.8 List of Router parameters

The following parameters are valid for the RO Router as well as for the Router function on the following devices:
EP1 Router-Sensor;
RB Router-Bridge;
RA Router-Actuator;
RC Router-Pulse Counter
Variable Index Name
IR0
'ON_LINE_STATUS'
IR1
'MACHINE_CODE'
IR2
'FW_VERSION'
IR3
'MAC_ADDR_0'
IR4
'MAC_ADDR_1'
IR5
'NETWORK_ID'
IR6
'QUALIY_CONN_SIGNAL'
IR7
'AP_RX_RADIO_LEV'
IR8
'ROUTER_NEARBY'
IR9
'ROUTER_GOOD_SIGNAL'
IR10
'CON NECTED_UNIT'
IR11
'RX_MESSAGE_CNT'

10.9 List of RA Router-Actuator parameters

Variable Index Name
HR0
CMD_PASSW_1
HR1
TRANSM_CYCLE
HR2
LO_TEMP_TRESHOLD
HR3
HI_TEMP_TRESHOLD
HR4
HYSTERESIS_SET
HR5
SET_POINT
HR6
MODE
IR0
MACHINE_CODE
IR1
FW_VERSION
IR2
TX_MESSAGE_CNT
IR3
RX_MSG_LEVEL
IR4
TEMPERATURE
IR5
MAC_ADDR_0
IR6
MAC_ADDR_1
IR7
ID_SER_ADDR
IR8
LAST_RX_DELAY
IR9
RX_MESSAGE_CNT
IR10
TIME_STAMP
IR11
AP_RX_RADIO_LEV
IR12
NETWORK_ID
IR13
'MIRROR_IS'
CS0
EN_CMD_PW
CS1
SET_RELE1
CS2
SET_RELE2
CS3
IN_1_POL
CS4
IN_2_POL
CS5
EN_NTC
IS0
HI_TEMP_ALARM
IS1
LO_TEMP_ALARM
IS2
RELE1_STATUS
IS3
RELE2_STATUS
IS4
IN_1_STATUS
IS5
IN_2_STATUS
IS6
PROBE_ERROR
Key:
HR = Holding register
IR = Input register
CS = Coil Status
IS = Input Status

10.10 Installation notes

1.
Remove the cover;
2.
Fasten the case to the wall with minimum two screws, remembering that this is a radio device and therefore the necessary details must be observed.
3.
Connect::
-
Power supply;
-
NTC temperature sensors (10K@25°C Beta(25/85) = 3435K) (models where featured);
-
Digital inputs (models where featured);
-
Analogue input (models where featured);
4.
Select the network address by dipswitch (for versions that feature the integrated functions).
5.
Open the Access Point wireless network (binding is performed automatically).
6.
Check the quality of the wireless signal.
7.
Close the device again.
8.
Make sure that the transmitter is in an optimum position with reference to the receiver, once installation is complete, checking the transmitted signal level in
the corresponding supervisor variable.
"Wireless probes" +0300030EN - rel. 1.0 - 16.07.2010
Description
'Slot status (0xFF=empty; 0=time out; 1=on)'
'Unit type - machine code (es: 101=Router Bridge 12..24Vac/dc; 108=Router 230Vac)' 101/108
'Firmware version (Major/Minor)'
'Units unique identifi er Mac-Address LSB'
'Units unique identifi er Mac-Address MSB'
'Network address '
'Quality signal (internal use)'
'Radio Lev. for AP Rx messages'
'Number of Routers nearby'
'Number of Router nearby with good connection'
'Number of Connected units (On-line units) End Devices to Router'
'Counter - AP Rx messages'
Description
'Command Password (1) '
'TX data cycle time '
'Threshold low Temp. '
'Threshold high Temp. '
'Hysteresis '
'Set point '
'Operating mode (0=off ; 1=cool,; 2=hot; 3,4,5= manual) '
'Unit type - machine code '
'Firmware version (Major/Minor) '
'Total Number of TX radio messages '
'Radio signal Level '
'Temperature Value '
'Unit unique identifi er Mac-Address LSB '
'Unit unique identifi er Mac-Address MSB '
'Carel_ID, Serial_Address, DIP-SW value '
'Time from last AP Rx message '
'Counter - AP Rx messages '
'Time stamp for Temp. readings (100*hour+minute) '
'Radio Lev. for AP Rx messages '
'Network address '
'Mirror Input Status (internal use)'
'Trig. PWD (internal use) '
'Setting of relay 1 (operating mode = 3 manual) '
'Setting of relay 2 (operating mode = 3 manual) '
'IN_1 Digital input polarity '
'IN_2 Digital input polarity '
'Enable Probe NTC '
'High Temperature Alarm '
'Low Temperature Alarm '
'Status Relay 1 '
'Status Relay 2 '
'Digital Input State IN_1 (1=open CA, 0=closed CC) '
'Digital Input State IN_2 (1=open CA, 0=closed CC) '
'Probe Failure Alarm '
Def.
Min
0
20
0
-500
300
-500
20
200
-500
0
69
2051
0
-
-
-500
-
-
-
-
-
-
-
-
-
0
0
0
0
0
1
-
-
-
-
-
-
-
44
Def.
Min
Max
UoM
-
0
1
-
-
-
-
2051
-
-
-
-
0
65535
-
-
0
65535
-
-
0
65535
-
-
0
255
-
-
0
100
dBm+100
-
0
16
-
-
0
16
-
-
0
32
-
-
0
65535
-
Max
UoM
0
65535
-
5
3600
sec
500
0,1°C
500
0,1°C
10
100
0,1°C
500
0,1°C
0
5
-
-
-
-
-
-
-
0
65535
-
0
100
dBm+100
1000
0,1°C
0
65535
-
0
65535
-
16
127
-
0
65535
-
0
65535
-
0
2359
hh*100+mm
0
100
dBm+100
0
65535
-
0
65535
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
0
1
-
"Type R/W"
R
R
R
R
R
R
R
R
R
R
R
R
Tab. 10.e
"Type R/W"
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
Tab. 10.f

Advertisement

Table of Contents
loading

Table of Contents