2.

WIRELESS REMOTE CONTROLLER

FEATURES
Simple function setting
z
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
z
Select from three different timer programs (ON/OFF/SLEEP).
ON-OFF Programmable timer
z
You can set an integrated ON-OFF or OFF-ON timer suitable for your life style.
(Setting time: 0.5, 1, 1.5, 2, 2.5, -----9.5, 10, 11, 12 hours)
Example of how to set the program timer.
From wake up to
go to work
PM11:00
12
set
OFF
PM9:00
9
3
10hours
set
6
ON
7hours
ON-OFF timer
Sleep timer
z
The sleep timer function automatically corrects the temperature thermostat setting according to
the time setting to prevent excessive cooling or heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
Switching remote controller custom code
z
Mixed-up
I.U.
I.U.
I.U.
I.U.
3 mode timer setup available (ON/OFF/SLEEP).
Easy operation.
Easy to change custom code (max. 4 custom codes) by button
operation.
From sleep to wake up
OFF
12
2hours
3
9
6
ON
9hours
OFF-ON timer
2 °C
1 °C
Code selector switch eliminates unit
After code change
being wrongly switched.
A
B
C
D
(Up to 4 custom codes can be set.)
I.U.
I.U.
I.U.
I.U.
*I.U.=Indoor unit
A
B
C
D
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
30min.
60min.
90min.
Timer setting
- (01 - 03) -
2 °C
3 °C
4 °C

Advertisement