Lamp Replacement procedure:
• Always wear antistatic gloves before starting this procedure
• Switch off and unplug the unit, wait 15 minutes until it is completely cooled
down
• Use the lock handles to lock the unit's tilt movement after setting it in a
position where the lens is facing the same direction as the LCD screen
• Use a screwdriver to open the cover of the head by removing the screw
• Remove the fan covering the lamp compartment
• Remove the lamp gently out of the lamp compartment
• Remove the cables from the lamp
• Attach the cables to the new lamp
• Gently insert the lamp into the lamp compartment
• If you touched the lamp with your bare hands, clean it with pure cleaning
alcohol thoroughly
• If necessary, you can adjust the lamp hotspot using the adjuster screw next
to the lamp
• Make sure no wires touch the lamp
• Reinstall the fan
• Place the cover back on the head and reinstall the screws
• Clear the running hours of the lamp in the Advanced Menu