6.
After the learning process, check the function of the
components and correct any errors detected.
By closing the contacts all locking devices belonging
to this radio switch (locking cylinders, shields) are
opened.
7.
Trigger the authorization:
After the start-up phase, the RF Switchpoint is always in the
"Not authorized" mode, i.e. the red LED is on.
A remote authorization is triggered by the closing of the two
contacts of the enable input (3). When the enable input is
actuated, the radio switch (1) is switched over into
"Authorization" mode, which is signalled by the green LED in
the radio switch.
When the contacts are closed, the Authorization mode is
switched on for about two seconds (default settings, adjustable
in the locking device).
If the authorization has been set correctly, the locking device
(2) should now signal free entry with its green LEDs (2 sec.).
Fig. 10 – Trigger the authorization