It is recommended that the nozzle be removed and cleaned daily.
D. Sanitizing:
Cleaning and Sanitizing are not required for potable water circuits. The potable water lines
should remain connected during the cleaning procedures for the concentrate circuits to avoid
contamination.
1. Disconnect concentrate container from product line.
2. Attach product line to container containing sanitizing solution mixed to mfg. recommendations
(50 ppm is recommended)
a. Using yellow Shut-off, turn incoming water off.
Sanitizing solution temperature should be between 70˚ to 100˚ F (max).
3. Prepare enough solution to sanitize from the concentrate source to the tea urn dispenser.
Alternate - using a fitment removed from a bag in box container. Attach fitment to concentrate
fitting. Prepare sanitizing solution in a container and set fitment/fitting assembly in solution.
4. Pull tea urn dispenser handle, solution will begin to flow towards dispensing valve.
5. When color turns clear, concentrate line is full of sanitizer solution.
6. Wait 15 minutes.
a. Reconnect concentrate product line.
7. Purge sanitizer from line with concentrate product.
8. Purge until concentrate is flowing from dispensing valve.
9. Using yellow Shut-off, turn incoming water on.
10. Taste the beverage to verify that there is no off taste.
FLUSH SANITIZING SOLUTION FROM CONCENTRATE LINE AS INSTRUCTED. RESIDUAL
SANITIZING SOLUTION LEFT IN SYSTEM COULD DAMAGE LINES AND DISPENSER PARTS.