Download Print this page

Schroeder America ARIZONA TEA DISPENSER 925 Installation Instruction, Parts List And Configuration Manual page 5

Arizona tea dispenser (tea urn)
Hide thumbs Also See for ARIZONA TEA DISPENSER 925:

Advertisement

Adjustment
C. To achieve the proper water flow rate, adjust the yellow/green screw within the flow control
module. For the mechanical application adjust the green metering screw (Fig. 4.2).
Depending on the pressure of the incoming plain water, the maximum flow may not be achievable.
1) Use slower flow rate. This will require ratio/brix adjustment.
D. To Ratio/Brix the final product, remove dispensing nozzle from valve.
E. Replace dispensing nozzle with the Schroeder America syrup separator nozzle. Rotate the
separator in position to ensure seal against the diffuser.
F. Adjust syrup flow to required ratio.
5. CLEANING AND SANITIZING
The Schroeder America Dispenser is shipped from the factory cleaned and sanitized in accordance
with NSF guidelines. The dispenser must also be cleaned and sanitized after installation is
complete. It is recommended that the operator provide continuous maintenance as required by the
manual and/or state and local guidelines to ensure proper operation.
A. External/Internal Cleaning Solutions:
Cleaners (ivory liquid, calgon, etc.) should be mixed with clean potable water at a temperature
of 90 to 110 degrees F. The acceptable mixture ratio is one ounce of cleanser to two gallons
of water. Any NSF approved equivalent cleaner may be used. Rinsing must be thorough using
clean potable water.
B. Internal Cleaning:
1. Remove top cover.
2. Wipe inside of the Tea Urn with a clean cloth mixed with the cleaner.
3. Inspect to make sure any product residue has been removed.
4. Dry with a clean soft cloth.
ONLY USE INTERNAL CLEANING SOLUTIONS THAT ARE APPROVED FOR BEVERAGE
DISPENSER APPLICATIONS, SUCH AS BevClean™. (NO CAUSTIC CHEMICALS SUCH AS
INDUSTRIAL KITCHEN CLEANING CHEMICALS SHOULD EVER BE USED)
C. External Cleaning:
The stainless steel urn can be cleaned by wiping with a cloth soaked with warm cleansing
detergent. Inspect the hose to ensure all residue is removed. Abrasive cleaning or scouring
pads should not be used as they will scratch the urn finish.
Slotted
Screw
Fig. 4.1
There are two solutions to this problem.
2) Add a water booster to the system.
Metering
Screw
Fig. 4.2
NOTE:
IMPORTANT
5

Advertisement

loading