(2)
Line Feed Motor
Resistance of each coil should be about 10.4Ω.
Signal
A1
A2
B1
B2
(3)
Space Motor
Resistance of each coil should be about 18.4Ω.
Signal
SP-U
SP-V
SP-W
SPA
SPB
+5V
EL
42089201TH Rev.4
Connector pin number
CN4
Connector pin number
CN2
18
17
6
22
21
200Ω
19
R1
20
1
2
3
4
SP
Motor
φA
φB
DA
Vcc
DK
G