Using The Install Wizard - Bosch Dinion IP 8000 MP NBN-80052 Installation Manual

Bosch dinion ip 8000 mp ip camera installation manual
Hide thumbs Also See for Dinion IP 8000 MP NBN-80052:
Table of Contents

Advertisement

26
en | Configuration
7.1.2

Using the install wizard

DINION IP starlight 8000 MP
1.
2.
3.
4.
2014.09 | v1.0 | AM18-Q0665
Power-up the camera and wait momentarily for it to start.
Briefly press the MENU button to open the wizard and
display the following screen on the monitor:
Lens type: DC Iris
CHANGE VARIANT
< press short >
The lens type is identified and shown on the screen.
The iris is opened to its maximum value.
If required, change the camera application variant as
follows:
Briefly press MENU until the required variant is displayed.
Choices are 1080p, 5MP (4:3) or 5MP (16:9).
Assign the setting by pressing MENU for a longer time.
Confirm the setting by pressing MENU for a longer time.
The camera reboots and assigns the factory defaults for
that variant.
When the variant is set correctly, briefly press MENU to
continue to the following screen:
Lens type: DC Iris
CONTINUE
< press short >
State: Ready
Focus indicator: 8
CONTINUE
< press long >
State: Ready
Focus indicator: 8
180° ROTATE
< press long >
DINION IP 8000 MP
Timeout: 300
Timeout: 300
Bosch Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dinion ip 8000 mp nbn-80122

Table of Contents