38
en | Troubleshooting
8.5

Terminal program

Data Terminal
If a camera cannot be found in the network or the connection to
the network is interrupted, you can connect a data terminal to
the camera for initial setup and for setting important
parameters. The data terminal consists of a computer with a
terminal program.
You require a serial transmission cable with a 9-pin Sub-D plug
to connect to the computer.
The communications accessory included with Windows can be
used as the terminal program.
1.
2.
Configuring the Terminal
Before the terminal program can communicate with the camera,
the transmission parameters must be matched. Make the
following settings for the terminal program:
Command Inputs
After the connection has been established, you must log on to
the camera to access the main menu. Other submenus and
functions can be accessed using the on-screen commands.
1.
2.
3.
2014.09 | v1.0 | AM18-Q0665
Disconnect the camera from the Ethernet network before
working with the terminal program.
Connect the serial interface of the camera using any
available serial interface on the computer.
19,200 bps
8 data bits
No parity check
1 stop bit
No protocol
If necessary, turn off the local echo so that entered values
are not repeated on the display.
Enter one command at a time.
When you have entered a value, such as the IP address,
check the characters you have entered before pressing
Enter to transfer the values to the camera.