Summary of Contents for Turbo Air Split wall-mounted Air Conditioner

  • Page 8 TAS-09EHU&TAS-09EHU/O,TAS-12EHU&TAS-12EHU/O TAS-18EHU&TAS-18EHU/O,TAS-24EHU&TAS-24EHU/O...
  • Page 16 failure code manual inverter single split series running lamp timer lamp failure The reason of fault and solution (flicker times) (flicker times) 1 、 Check whether the connection of the outdoor unit and indoor unit is one to one, otherwise connect the L, N and communication line of the indoor unit and outdoor unit one to one.
  • Page 17 1、 Check whether the connection of the compressor is reliable, otherwise connect firmly again. module of outdoor Light 2、 Check whether the fixation between the IPM module unit fault and the radiator is firm. 3、 Check if the compressor is well, otherwise replace it. 4、...
  • Page 18 inductor of Check whether inductor of current or voltage have been Light current or voltage damaged, they should be replaced if they are fault. fault 1、 Power on again, and check the operation of the compressor is normal. 2、 Check whether the connection of the compressor is reliable, otherwise repair.
  • Page 19 1、 Check whether the air condition system and pressure discharge temp. of are normal. Light compressor 2、 Check whether the sensor, connecting wire of the protection sensor and the detection circuit are abnormal. 1 、 Check whether the air condition system and pressure over heat of are normal.