Safety instructions PLEASE READ THE FOLLOWING SAFETY •This unit must be grounded in accordance with local INSTRUCTIONS BEFORE INSTALLING AND electrical codes. OPERATING THE UNIT: •Connect wires and pipes securely and tightly as loose connections/ wiring may cause overheating at This air conditioner meets strict safety and operating connections and a possible fire hazard.
Disposal of Used Electrical & Electronic Equipment The meaning of the symbol on the product, its accessory or packaging indicates that this product shall not be treated as household waste. Please, dispose of this equipment at your applicable collection point for the When Servicing: recycling of electrical &...
Below is an overview for the connection of the the Indoor unit to the Outdoor unit. The pages following will give detailed instructions for full installation. Remember to read the complete Installation section and follow all the safety instructions fully when installing the Indoor and Outdoor units. OVERVIEW 16.4 49 Ft 16.4Ft 0.5 oz TAS-09SVH/125SVH TAS-09SVH/12SVH...
Select an approximate position for the unit, taking the required distances away from walls/AC outlet into consideration. TAS-09SVH DSB-0910L/LH, DSB-1210L/LH DSB-F0910PH-DV, DSB-F1210PH-DV TAS-12SVH CAUTION Before making hole, make sure there are no studs, pipes, electrical wiring or conduit directly behind the area to be cut.
CONNECTING COPPER TUBES To connect the copper tubes, follow the procedures below: 1. At flare working, put the copper tube into standardized dimensional hole of the bar to work at over “ ” size from the surface of the bar. (Do flare work after remove all burrs) •...
Page 8
• Working dimension according to copper tube Pipe(Ø) B (in) A (Ø) Torque 3. After align the center of the copper tube sufficiently tighten the flare nut by hand and to connect as turning by spanner. Follow the procedures below. (To prevent gas leakage, apply refrigeration machine oil on both inner and outer surfaces of the flare nut) Union Bolt...
CONNECTING THE DRAIN HOSE To connect the drain hose, follow the procedures below: 1. Drain hose have to be descends to outdoor. 2. Do not install drain hose.(see below) Less than 2.0in Installed at Tip of drain hose Bent Gap is not enough Tip of drain hose dipped in water high position...
TEST RUN Check that all tubing and wiring have been completed correctly. Check again that the wide and narrow tube service valves are fully opened. Turn on the power and run the system. Service Valve Construction Valve Position Closed The valve systems of both the wide and narrow tubes are turned all the way in. The unit is shipped from the factory in this position and it is also used for Pump Down and Air Purging.