Turbo Air TAS-09EHN Owner's Manual
Turbo Air TAS-09EHN Owner's Manual

Turbo Air TAS-09EHN Owner's Manual

Inverter one- one split-type room air conditioner

Advertisement

Inverter One- One Split-Type

ROOM AIR CONDITIONER

TAS-09EHN
MODEL #:
TAS-12EHN
TAS-18EHN
TAS-24EHN
C M
U S
Please read this manual carefully and thoroughly before
operating the unit.
If you still have any difficulties or problems, consult your
dealer for help or Turbo Air Conditioning Corp.
Please keep this manual handy.
W1

Advertisement

Table of Contents
loading

Summary of Contents for Turbo Air TAS-09EHN

  • Page 1: Room Air Conditioner

    TAS-09EHN MODEL #: TAS-12EHN TAS-18EHN TAS-24EHN Please read this manual carefully and thoroughly before operating the unit. If you still have any difficulties or problems, consult your dealer for help or Turbo Air Conditioning Corp. Please keep this manual handy.
  • Page 2: Table Of Contents

    CONTENTS SOCIABLE REMARK Sociable remark........................2 SAFETY PRECAUTIONS Warning ..........................3 Caution ...........................4 OPERATING INSTRUCTIONS Parts names ..........................5 Special functions ........................6 Operating temperature......................7 Manual operation ........................7 Airflow direction control ......................8 How the air conditioner works ....................9 CARE AND MAINTENANCE Care and maintenance ......................10 OPERATION TIPS Operation tips ....
  • Page 3: Sociable Remark

    SOCIABLE REMARK When using this air conditioner in the European countries, please read the following information: DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 5: Caution

    SAFETY PRECAUTIONS CAUTION Ventilate the room well When the air filter is to be Do not put objects like thin when used together removed, do not touch the rods into the panel of blower with a stove, etc. metal parts of the unit. and suction side.
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS Indoor unit Indoor unit 1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6. Vertical air flow louver(inside) 7. Display panel NOTE: The actual shape of the indoor unit you purchased may be slight different on front panel and display window.
  • Page 7: Special Functions

    OPERATING INSTRUCTIONS Special functions Refrigerant Leakage Detection With this new technology, the dipsplay area will appear EC and the indication lamps continue flashing when the outdoor unit detects refrigerant leakage. Louver Angle Memory Function(optional): Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will memorize the boundry of safety angle.
  • Page 8: Operating Temperature

    OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details. Operating temperature Mode Cooling operation Heating operation Drying operation Temperature Room temperature Outdoor temperature For the models with low temperature cooling system NOTE: 1.
  • Page 9: Airflow Direction Control

    OPERATING INSTRUCTIONS Airflow direction control Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures. Adjust the horizontal/vertical louver using the remote controller. For some models, the vertical louver can only be adjusted manually. To set the horizontal/vertical air flow direction Perform this function while the unit is in operation.
  • Page 10: How The Air Conditioner Works

    OPERATING INSTRUCTIONS How the air conditioner works SLEEP operation AUTO operation 7 hours timer off When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on set temperature and the room temperature. Temperature The air conditioner will control room temperature 1 hour...
  • Page 11: Care And Maintenance

    CARE AND MAINTENANCE Care and Maintenance Cleaning the Grille, Case and Remote Controller Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTE: Power supply must be disconnectd before cleaning the indoor unit.
  • Page 12 CARE AND MAINTENANCE 4. Remove the Air Freshening Filters from its supporting frame (The solution to disassemble may differ from each other for different filters. Refer to Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place.
  • Page 13: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 14 OPERATION TIPS 8. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 9.
  • Page 15: Troubleshooting Tips

    TROUBLESHOOTING TIPS Troubleshooting Tips If one of the following faults occurs, stop the air conditioner immediately, disconnect the power and then connect it in again. If the problem still exists, disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators continue flashing.
  • Page 19 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. 2020001B3331...

This manual is also suitable for:

Tas-12ehnTas-18ehnTas-24ehn

Table of Contents