Iv.7 Test Menu : Test And Version Display - Bodet HMT Installation Instructions Manual

Led display time and temperature display
Table of Contents

Advertisement

21. The figure flashes (0 to 9). Modify with the [R] button.
22. Press the [S] button to validate and move on to setting of
the tenths of a degree of the temperature correction.
23. The figure flashes (0 to 9). Modify with the [R] button.
24. Press the [S] button to validate.
25. Select the channel (1 to 8 or none) of the HF transmitter on
which synchronisation is required. Enter the same number
as in the HF temperature box. The value – deactivates the
HF temperature function. Modify with the [R] button.
26. Press the [S] button to validate the temperature unit and
move on to setting of the correction to be made to the
humidity reading.
27. The figure flashes (-9 to +9). Modify with the [R] button.
28. Press the [S] button to validate. The display returns to
normal mode.

IV.7 TEST menu : test and version display

1.
Enter the TEST menu (see page 15).
2.
All the LEDs should light up.
3.
Press the [S] or [T] to go on to the next test.
4.
All the LEDs should go out.
5.
Press the [S] or [T] button to display the version.
6.
Display of addressing number of each module (the "3-dot"
module remains unlit). The number normally corresponds
to the example on the right.
7.
Display the soft version number.
8.
Press the [S] or [T] to return to normal mode.
32