According to the place, it might be necessary to adjust the measured values.
If necessary use an accurate thermometer/hygrometer to adjust the offset from
the TECH menu (page 31).
Humidity probe
over support
Humidity probe
connector
Green
Yellow
White
Brown
III.10 Installation of hard-wired temperature sensor
Attach the temperature sensor in a well-ventilated place sheltered from sunlight
and rain (for outdoor installation). The position of the sensor must be carefully
chosen to ensure correct temperature reading.
Avoid external walls, heat sources, metal parts and draughts (for further
information, refer to the meteorological standards).
The sensor is set in the factory to 20°C. It may be necessary to adjust this
setting in accordance with the length of the cable (30 metres maximum):
- Place an accurate thermometer near the sensor.
- Adjust the temperature if necessary using the correction in the PROG menu
(page 31).
Connect the sensor to the terminal strip (B) of the electronics board.
16
D
C
3,3V
0V
Air temperature sensor attachment point. If possible, avoid
placing the resin part in contact to prevent thermal
conduction.
Data
White
0V
Brown
Hard-wired temperature
sensor connector