Installment Of Mg; Wire Arrangement Of Each Mg And Soldering - Nikon D200 Repair Manual

Hide thumbs Also See for D200:
Table of Contents

Advertisement

Installment of Mg

・ When mount each Mg, arrange clearances between the U-groove lever and the
iron core.
Check the clearances when the iron core of Mg is attached.
Adhesive:
Screwlock
#134×2
Aperture-start Mg (#133)

Wire arrangement of each Mg and Soldering

Mirror-drive Mg (#131)
#134×2
Adhesive:
Screwlock
#134×2
Adhesive: Screwlock
Aperture-stop Mg (#135)
- A10 ・
U-groove lever
Ratchet gear
0.2 ~ 0.3
When the aperture-stop Mg is attached, in order to
leave clearances of 0.2-0.3 mm between the ratchet
gear and locking lever, put the 0.2-mm washers, etc,
in the clearances, and fix the Mg with two screws
(#134).
-
INC
VBA13001-R.3677.A
Iron core of Mg
Locking lever