Cell Tower
Outside Antenna Installation
The antenna should be mounted as shown in the illustration
above . The mounting bracket, included with antenna, is adjustable
and will accommodate pipe diameters from 1 .25" to 2" (pipe sold
separately) . Mount the antenna so that there is at least 3 feet of
clearance in all directions around it . Position the antenna so that
it has an unobstructed line of sight to the cell tower's strongest
signal . Make sure the antenna is not pointing across your own roof
or at the inside antenna as this will cause the oscillation protection
circuitry to shut down the signal booster .
Warning:
Lightning protection is recommended for all installations
(Part #859902 or 859988) . Take extreme care to ensure that
neither you nor the antenna comes near any electric power lines .
Installing Lightning Protection
Install the Lightning Surge
Protector (LSP) close to
the signal booster . Attach
the cable from the outside
antenna to the surge
protector, using a short length
of low loss cable; attach
one end to the LSP and the
other to the outside antenna
connector on the signal
booster . Attach a ground
wire to the LSP . (For AG Pro
70 use Part# 859988 75 Ohm
Lightning Surge Protector) .
7
Contact Wilson Electronics Technical Support Team with any questions at 866-294-1660
or email: tech@wilsonelectronics.com. Hours: 7 am to 6 pm MST.
Drip hole on bottom
To the outside antenna
Ground Wire
Lightning Surge
Protection
Signal Booster