5.5 System parameters
Parameter
Value
61
The Brave‟s comes with standard acoustic signals. However, using parameter
"z" it is possible to switch off the acoustic signals. The values are:
z=0
Acoustic signals off; and
z=1
Acoustic signals on.
Parameter
Value
62
The acoustic signals for the connection and disconnection of a line are standard,
but this may cause false choices with some phone systems. So using parameter
"v" it is possible to switch off these signals. The values required are:
z=0
Introduction/conclusion signalisation is off;
z=1
Pick up and disconnection signalisation on (intro/concl.- type1);
z=2
Pick up and disconnection signalisation on (intro/concl.- type2).
Parameter
Value
63
Ticking during a call is switched off as standard. However, by switching it on you
can differentiate on the switchboard a call from the Brave by a faint ticking. The
values are:
u=0
Ticking into a call is off
u=1
Ticking into a call is on
Parameter
Value
65
The signal for switching on a relay is standard, z=0. However, it is possible to use
this function when using a uni-directional supply 12V, so when the door lock is
open there is no buzzing so the person at the door won‟t know the door is open.
When set to z=1 the time the relay is switched (door open) then there is a
specific sound.
Note1 This function is available only for regimes m=1
Note2 During the relay switch-on (2 impulses) there is acoustic signal for the
whole time of the sequence (even during gap between impulses).
Meaning
Acoustic signals (confirmation, error,empty
z
memory, end of call)
Meaning
Acoustic signals introduction/conclusion
v
Meaning
Acoustic ticking signal during a call
u
Meaning
Acoustic signals for switching on a relay
z
BRAVE SlimDP –
User and service manual
Basic
1
(0/1)
Basic
1
(0/1/2)
Basic
0
(0/1)
Basic
0
(0/1)
37