5.4 Time parameters

Parameter
Value
51
q – The number of rings before an incoming call is picked up. The Brave
picks up between rings 2 secs. after detecting the q-th ring. It is possible
to set the number of rings between 1 and 9.
Parameter
Value
52
d – The maximum length of time for which the Brave is
busy. It is possible to prolong this time during the
call by choosing a key (* or #) from the phone
(
parameter 42
accordance with the adjacent table.
Parameter
Value
53
w – maximum time [in seconds] between button presses [range 1 - 9]
Normal buttons
Relay switch on – if the time between presses is longer than time w,
-
then the code will not work correctly.
Choice of number – if the pressed button is the first number of a
-
password to switch on a relay then the choice is delayed by time w.
.
Parameter
Value
54
z – Time [secs.] the Brave disconnects before it picks up again for repeat
dialling (press of a button during a call, detection of busy tone) [range 1-
5].
Meaning
Number of rings before the Brave picks up
q
Meaning
d
Maximum length of a call
). The setting of this time is in
Meaning
w
Time between button presses
Meaning
Time of disconnection for repeat dialling
z
BRAVE SlimDP –
User and service manual
Basic
(1-9)
Basic
(0-9,*,#)
Time
Option
[min]
0,5
1 - 9
15
30
Basic
(1-9)
Basic
(1-5)
2
2
0
1 - 9
*
#
2
2
33