2.1.3 Wiring and wall mounting

5. Use the wall mounting
template at the end of
the manual to mark the
position for the screw
holes
and
connection
mounting surface. Drill
the holes.
6. Feed
the
(analogue
supply,
lock
figure - 6) through the
cable hole.
Fix the panel to the wall
using the screws and
rawlplugs supplied.
Drill draw is on page 52
Note: Some materials such as metal and wood may require special
screw types.
To power the unit for voice, connect the telephone wires into the terminal
(on the right side). Using either a standard analogue phone line or an analogue
extension on a PBX.
For the external power supply, connect to the terminal "12V" external power
supply AC min. 10V / max. 18V or DC min. 12V / max. 24V.
The energy consumption of a connected electrical (magnetic) lock (0,5A –
1,0A) determines the load on the power supply. If you activate the heating
feature the PCB current will climb to about 150mA. We recommend power
supply AC 12V/1A for normal version and we recommend power supply DC
12V/1A for version with amplifier.