Disk Drive Status Indicators - HP StorageWorks 2500 User Manual

Disk system
Table of Contents

Advertisement

1. Ready
2. Online
3. Fault
Figure 28 Disk drive status indicators
Table 1 1 Disk drive status indications
Ready
On
Flashing
On
On
Catastrophic errors
The design of the DS2500 allows it to continue operating in the presence of faulty hardware. However, a
critically-high temperature in the enclosure can cause hardware failure and compromise data integrity. To
prevent catastrophic data loss and further damage to components, the following conditions cause the
DS2500 to shut down:
A power supply removed from the enclosure
No operational blowers
An unacceptable temperature level in the enclosure
If any of these conditions exists, the EMU starts a timer to shut down the enclosure in 7 minutes. If the
condition is corrected before the 7 minute countdown is completed, the EMU aborts the shutdown
and normal operation resumes.
52
Troubleshooting
Online
Fault
On
Off
On
Off
On
On
Off
Flashing
Description
Normal operational status.
Drive is idle.
Normal operational status.
Drive is being accessed.
Displays on the first disk in the enclosure to indicate
the disk drive is not connected to either I/O module.
Verify the FC cable connections to an HBA.
Indicates disk drive error/not active.
Verify FC loop continuity.