Prescribe Frpo D0 Command - Kyocera FS-1010 Operation Manual

Ecosys page printer
Hide thumbs Also See for FS-1010:
Table of Contents

Advertisement

RS-232C/RS-422A Protocol
B.4.1 PRESCRIBE FRPO D0 Command
Timing of XON transfer to
host while Ready or Waiting
H5: Protocol logic
Parameter value
0
1
2
3
4
5
The factory setting is 0.
H6: Buffer nearly-full threshold
This is a percentage from 0 to 99. The factory setting is 90.
H7: Buffer nearly-empty threshold
This is a percentage from 0 to 99. The factory setting is 70.
The factory settings of the buffer nearly-full and nearly-empty thresholds
(H6 and H7) are subject to change without notification.
The gap between the nearly-full and nearly-empty thresholds allows the
computer to send a fairly large amount of data in a continuous stream.
H8: Received-data buffer size
This is the size of the input buffer, specified in units of 10 Kbytes. The
factory-set value is 6, meaning 60 Kbytes.
Since DTR/DSR protocol is not used with the RS-422A standard, select a
parameter value other than 0, 1, or 2 for the H5 setting when using the
RS-422A interface.
The PRESCRIBE FRPO D0 command provides control over XON/XOFF
operation when an error occurs on the serial interface. The following table
summarizes the error status corresponding to different D0 values.
XON sent every 3-5 seconds
XON not sent
Meaning
Combination of 1 and 3 below
DTR/DSR, positive logic
DTR/DSR, negative logic
XON/XOFF
ETX/ACK
XON/XOFF recognized only as protocol
Serial interface error
Error not handled
D0=0 (default)
D0=10
B-11
Error handled
D0=1
D0=11

Hide quick links: