Chaffoteaux & Maury Britony SE 80 Nat Operating Instructions Manual
Chaffoteaux & Maury Britony SE 80 Nat Operating Instructions Manual

Chaffoteaux & Maury Britony SE 80 Nat Operating Instructions Manual

Combination boiler heating and instantaneous domestic hot water fanned flue system

Advertisement

COMBINATION BOILER

Heating and Instantaneous Domestic Hot Water
Fanned Flue system
Installation and Operating instructions
These instructions Must Be Left With The Appliance.
Manufactures N°
200906812037.31
200906812027.31
200906813037.31
200906813027.31
GB
IE
2
3
1
0
4
bar
2
1
3
0
4
bar
Model Type
Britony SE 80 Nat
Britony SE 80 L.P.G.
Britony SE 100 Nat
Britony SE 100 L.P.G.
Gas Council N°
47 - 980 - 16
47 - 980 - 18
47 - 980 - 17
47 - 980 - 19
c

Advertisement

Table of Contents
loading

Summary of Contents for Chaffoteaux & Maury Britony SE 80 Nat

  • Page 1: Combination Boiler

    Installation and Operating instructions These instructions Must Be Left With The Appliance. Manufactures N° Model Type Gas Council N° 200906812037.31 Britony SE 80 Nat 47 - 980 - 16 200906812027.31 Britony SE 80 L.P.G. 47 - 980 - 18 200906813037.31...
  • Page 2: Customer Care

    These instructions are suitable for the following boilers : Britony Combi SE. 80 Britony Combi SE.100 Do not forget the Log Book! Chaffoteaux & Maury supports Benchmark, the heating industry code to ensure the correct installation, commissioning and servicing of domestic central heating systems. To The Householder Make sure you have a completed Log Book for your boiler.
  • Page 3: Table Of Contents

    Contents Page Page CUSTOMER CARE ..........DHW ..............Guarantee............Central Heating............ Statutory Requirements........Lighting the boiler ..........CONTENTS............Post Commissioning..........INTRODUCTION ..........Handing over to the Householder......DESCRIPTION ............ SYSTEM GUIDANCE.......... Location of components ........Showers............... TECHNICAL DATA..........Flushing and Water Treatment ......DIMENSIONS............
  • Page 4: Description

    Description Location of components 1. - Air pressure switch 2. - Steel chassis complete with expansion vessel 3. - Main heat exchanger 4. - Combustion chamber 5. - Multi- gas burner assembly comprising ignition and ionisation electrodes 6. - Automatic air separator and automatic vent 7.
  • Page 5: Technical Data

    Technical Data Britony combi SE.80 SE.100 Britony combi SE.80 SE.100 PROPANE L.P.G. G31 Appliance category Cat II Cat II 2H 3+ 2H 3+ Gas rate Heat input C/H & DHW Gross Maximum in kW 28.7 34.6 Maximum in kg/h 2.00 2.42 Maximum in Btu/h 98000...
  • Page 6 Dimensions (continued) Outer case dimensions : - Width : 440 (minimum space required 450) - Height : - Depth : All dimensions in mm Safety valve center line 54 54 54 54 Fig. 4 J K L M N Minimum clearances : - Both sides 5 mm The boiler is suitable for the flue types:...
  • Page 7: Operation

    Operation reset Fig. 6 Domestic Hot Water Mode stage solenoid b Fig. 7 opens to allow the full gas rate. If a In order to supply hot water, the main switch 19 Fig. 6 flame is not detected, after 8 seconds, the security must be in ON position I This will be confirmed by the solenoid closes and shuts off the gas.
  • Page 8: Installation Requirements

    Installation Requirements Location It may be necessary to protect the terminal with a guard. Reference The boiler can be installed on any suitable internal wall. Provision should be made to the Building Regulations for guidance. Suitable must be made to allow the correct routing of the flue and siting of the guards may be obtained from the following manufacturer: terminal to allow the safe and efficient removal of the flue products.
  • Page 9: Connecting The Boiler To The System

    Installing the Boiler (continued) Fig. 10 Fig. 9 Place the boiler on the wall on the hanging bracket. If required, there is space for all piping to pass behind the boiler. Using fig. 11 for reference, connect the gas and water pipes and the valves to the base of the appliance using the tails provided.
  • Page 10: Adjustement

    Installing the Boiler (continued) Room thermostat T.A. Connector C F1 F1 main supply cable Fig. 13 ADJUSTMENT Choice of mode : - Function without room thermostat bridge “S” remains in place. Function with room thermostat remove bridge “S”, room thermostat connected as shown on connector “C” (fig. 14). The external control switches both burner and pump.
  • Page 11: Commissioning And Testing

    Commissioning and Testing Pre-commissioning Turn the boiler thermostat to maximum 21 (fig 18). Ensure that the system has been adequately flushed. The boiler will light. Purge gas supply of air and test for soundness. Allow the boiler to heat system. Carry out final electrical tests to ensure the correct polarity Check the inlet gas pressure (working pressure) while and earthing continuity.
  • Page 12: System Guidance

    System Guidance The boiler is suitable for sealed systems only. The Fernox Manufacturing maximum cold water mains pressure for the appliance is Britannica Works 10 bar. All fittings and pipework connected to the Clavering appliance should be of the same standard. If there is a Essex possibility of the incoming mains pressure exceeding 10 CB11 4QZ...
  • Page 13: User's Instructions

    User’s Instructions Control panel 19. Two position Selector switch reset O = Switched OFF I = Switched ON = Domestic hot water temperature adjustment = Heating flow temperature adjustment 22. Heating temperature indicator lights Green indicator - Power ON Fig. 22 Orange indicator - Burner ON Red indicator - Lock out / flame failure 26 “RESET”...
  • Page 14: Instruction For Setting The Built In Clock

    Instruction for Setting the Built in Clock (if fitted) 1. General layout The mechanical clock covers a 24 hour period. Each tappet represents 15 minutes A (fig. 25). An override switch is located on the clock B (fig 25). 2. To set the time To set the time of day, grasp the outer edge of the dial and turn slowly clockwise until the correct time is lined up with the arrow C (fig.
  • Page 15: Incorrect Function

    Incorrect Function Incorrects functions is signalled by leds (rep 22) display flashing correspond with chart below. CODE FAULT Overheat sensor switch open. Overheating defect without lock out. No flame detection. Ionisation printed circuit board faulty. Antifrost mode on (pump in operation). Antifrost mode on (burner and pump in operation).
  • Page 16 This appliance is suitable for Natural gas or LPG. A gas conversion must be made by a competent person. Chaffoteaux & Maury are continuously improving their products and therefore reserve the right to change specifications without prior notice and accepts no liability for any errors or omission in the information contained in this document. Manufacturer: Chaffoteaux &...