COMBINATION BOILER Heating only (system) Heating + sanitary hot water together (system plus) Open flue System Installation and Operating Manual MODE AUTO TEMP...
2. Dimensions Measurements in mm Safety valve outlet ø Heating flow and tank Tank backflow (system plus) Gas inlet Cold water supply Heating backflow 175,3 Weight with packaging: 24 kW: 29 kg 172,5 121,5 J K L M N 450 min. for maintenance 450 mini pour entretien 54 54 54 54 ▲...
4. Installation requirements 4.1 REGULATIONS 4.2 BOILER LOCATION PRIVATE HOMES - install the boiler near a duct for removing the products of combustion STATUTORY REQUIREMENTS FOR INSTALLATION AND MAINTENANCE - never install the boiler above hot-plates or ovens or in general over any equipment producing greasy vapours Installation and maintenance of the equipment must be car- which could make the boiler dirty and affect its operation...
5. Fitting the boiler - place the paper installation jig in the selected position on the wall - fit the hanging bracket - bring the water pipes and the electrical connection to the locations shown on the fitting template - remove the 2 locking screws A which secure the front panel (fig. 7) - remove the front panel - offer the boiler up to its bracket and allow it to drop into position while pressing on it (fig.
6. Electrical connections Regulations: - in accordance with the regulations, an all-pole iso- lating device with a contact opening gap of at least 3 mm must be installed in the boiler's stationary power supply installation - the boiler must be connected to a fixed junction box using the cable supplied Location of connections: - the 230 V supply lead and room thermostat inputs...
7. Operating PRESSURISATION (fig. 12) Heating circuit and tank: - open cold water tap 34 - check that the heating flow 31, heating backflow 35 and tank backflow 32 taps (compy system plus) are open - open filling tap 36 - close the tap again when the needle of pressure gauge 19 (fig.
7. Operating (continued) Célectic Tempo Débistat Sanitaire 1,5 sec Tempo Débistat Sanitaire 0 sec TIC 3 min. TIC 30 s. Post-circulation 30 s. Post-circulation 3 min. Post circulation 30 s Post circulation 3 mn Modulating Operation ON/OFF operation Fonctionnement Modulant Fonctionnement TOUT OU RIEN Heating setting to 40 °C Consigne chauffage à...
8. Fitting the casing Fitting the casing Remove the protective film on the casing: - offer up the casing (fig. 14) - engage hooks N in notches R operation 1 - fit the top of the panel in place - screw in the 2 front panel securing screws A Note: it is essential to refit both locking bolts A Fig.14 Fig.15...
9. Gas conversion When changing to a gas different from the one for which the boiler is equipped, you should replace the parts supplied with the conversion kit and adjust the gas valve in accordance with the method described below. Adjusting the nominal output •...
10. Fault codes - Information If the equipment has an operating fault, one or more LEDs (23) flash according to the type of fault listed in the table below. LED Coding FAULT DESCRIPTION INFORMATION 30 40 50 60 70 80 H H H H H H H H H H G G Locked - overheating.
INSTRUCTIONS FOR THE USER 12. Controls (system plus) Fig.20 Control panel (fig. 20) Taps and valves (fig. 21) 19. - heating circuit pressure gauge 31. Central heating flow isolating valve and tank 32. Tank backflow (system plus) 20. - ON/OFF push button and ON indicator light 33: Gas tap 21.- domestic hot water function ON and hot water 34: Cold water supply tap...
13. Operation Starting up 1. check that the appliance's general gas shut-off tap is open and that the boiler is supplied with power. 2. check that there is sufficient pressure in the heating circuit: pressure gauge needle at least 1.2 bar with 1.7 bar at max. cold 3.
14. Maintenance Current legislation requires a mandatory annual service of your water heater. Once a year, have it checked by a qualified professional. Annual service contract formats may be suggested to you by service providers for all boiler servicing. Contact your gas fitter or our commercial services.
16. Warranty Your boiler is under warranty. The warranty certificate specifies the warranty conditions: check that the detachable section of this certificate has been returned to Chaffoteaux & Maury. A qualified professional must have installed, adjusted and commissioned your installation for the warranty to be valid. This assures you that the fitter complied with the installation manual and that regulatory and safety conditions have been met.
18. Technical specifications Model 24 kW CF 7,5 - 24 KW Heating power 24 kW Variable tank pre-heating power Pn max Class I - type B11BS (natural draught/chimney/overflow safety device) Category II 2E+3+ Fresh air flow rate required for combustion 48 m Combustion products mass flow rate 20 g/s...
19. Operating faults Fault Cause Solution Control gas, water and electrical The boiler doesn’t start No gas, no water or no electricity supply, fuses… Air in the gas pipe Follow procedure in chapter 8 Room thermostat switched off Set up the room thermostat Wait for a few minutes Press on reset button 25 (fig.20) the red led turn off and the boiler attempts to re-...