Chaffoteaux & Maury Britony Combi SE Maintenance And Service Manual
Chaffoteaux & Maury Britony Combi SE Maintenance And Service Manual

Chaffoteaux & Maury Britony Combi SE Maintenance And Service Manual

Fanned flue combination boiler heating and instantaneous domestic hot water

Advertisement

c
Heating and Instantaneous Domestic Hot Water
Dimensions
2
3
1
0
4
bar
2
1
3
0
4
bar
The boiler is suitable for the flue types:
• type C 12
• type C 32 xx or C 32 xy
• type C 52

Technical data

Heat input C/H & DHW
Gross
Heat output C/H & DHW Combi 80 :
Gross
Max. operating pressure C/H circuit
Expansion vessel net capacity
Expansion vessel initial pressure
Electrical consumption
Voltage
Electrical protection index
Fuses
Nominal gas flow rate at 15°C and 1013 mbar
- Natural gas ( G 20) at 20 mbar
- Butane gas ( G 30) at 28 mbar
- Propane gas ( G 31) at 37 mbar
Injectors and gas valves seat diameter
- Solenoid restrictor diameter
- Gas valve restrictor diameter
- Manifold injectors (16)
MAINTENANCE AND
SERVICE GUIDE
Fanned Flue Combination Boiler
Fig. 1
Combi 80 :
11.73 to 28.70 kW
Combi 100 :
15.43 to 34.5 kW
9.5 to 24 kW
Combi 100 :
12.5 to 28 kW
:
2.5 bar
:
5.44 l
:
0.7 bar
:
150 w Max 3.4 w Min
:
220-240 v
:
IP44
:
2 A and 1.25 A
Maximum
power 24 kW
2.74 m
2.04 kg/h
2.00 kg/h
Natural gas
2.60 mm
6.70 mm
1.23 mm
These Instructions Must Be Left With The Appliance.
212
721
850
380
Outer case dimensions :
- Height : 850
- Width : 440 (minimum space required 450)
- Depth : 380
DHW flow rate at @ 30°C Combi 80 :
DHW flow rate at @ 35°C Combi 80 :
Minimum DHW operating flow rate
Minimum DHW working pressure
Maximum DHW working pressure
Gas category
BRITONY Combi SE 80
Minimum
power 9.5 kW
3
/h
1.22 m
0.91 kg/h
0.89 kg/h
BRITONY Combi SE 80
Butane or Propane
1.75 mm
4.90 mm
0.70 mm
360
50
67
235
232
54 54 54 54
88
J K L M N
I
Combi 100 :
Combi 100 :
BRITONY Combi SE 100
Maximum
power 28 kW
3
/h
3.34 m
3
/h
2.45 kg/h
2.42 kg/h
BRITONY Combi SE 100
Natural gas
2.90 mm
no resrictor required
1.26 mm
All dimensions in mm
L
J K
M N
32
I
Safety valve outlet
J Heating flow
K D.H.W. flow
L Gas supply
M Cold water inlet
N Heating return
11.4 l/min
13.4 l/min
9.85 l/min
11.48 l/min
:
2 l/min
:
0.5 bar
:
10 bar
:
II 2H 3+
Minimum
power 12.5 kW
1.57 m
3
/h
1.17 kg/h
1.15 kg/h
Butane or Propane
2.00 mm
6.70 mm
0.76 mm

Advertisement

Table of Contents
loading

Summary of Contents for Chaffoteaux & Maury Britony Combi SE

  • Page 1: Technical Data

    Voltage 220-240 v Electrical protection index IP44 Fuses 2 A and 1.25 A Nominal gas flow rate at 15°C and 1013 mbar BRITONY Combi SE 80 BRITONY Combi SE 100 Maximum Minimum Maximum Minimum power 24 kW power 9.5 kW power 28 kW power 12.5 kW...
  • Page 2: Pump And Expanssion Vessel Characteristics

    Pump and expanssion vessel characteristics System capacity chart Pression à froid pour le circuit chauffage (en bar) Pressure PUMP HEAD AVAILABLE Pression disponible Minimum flow rate (with all heating thermostatic valves closed) Débit mini (robinets thermostatiques fermés) 40°C 50°C 60°C 70°C 80°C 1100...
  • Page 3: Control Panel

    FUNCTIONING Switching on 1) Check that the gas service tap is opened at the gasmeter and main power is on. 2) Check that pressure in central heating system is above 0.8 bar and below 1.5 bar with the pressure gauge 3) Open the gas tap 3.
  • Page 4 2) If the room thermostat (if fitted), the will now circulate primary water heated by When there is a demand for heating boiler temperature control and the the main heat exchanger through the sec- (either from the room thermostat or the clock (if fitted) are all calling for heat, the ondary heat exchanger.
  • Page 5: Air Pressure Switch

    ADJUSTMENTS ON CONTROL PCB Adjustment on the PCB : - P3 : potentiometer TAC (Temporisation Anti Cycle) may be adjusted between 30 seconds and 3 min- utes (see detail) (factory set at 3 minutes). - JP3 : the spade connector allows the gas rate to be reduced to 1/3 performance by positionning spade across pins as shown A Full performance across pins as shown B.(factory...
  • Page 6: Removal And Replacement Of Parts

    REMOVAL AND REPLACEMENT OF PARTS Before removing appliance case, isolate 10. Pressure Switch 5. Ignition Electrodes the gas and electrical supplies. Isolate Carry out steps 1 and 2 as above. remove Remove outer case and sealed chamber boiler from the system and drain before the wiring cover undo the power lead plug front panel as in steps 1 and 2.
  • Page 7 15. 3-Way valve 18. Pump 21. Safety thermostat Drain boiler as in step 12. Remove the 2 Drain the boiler as in step 12. Open the Remove the casing as step 1 unscrew four self tapping screws securing the clips on the 3 way valve hydraulic motor electrical box cover removing the 2 sealed chamber front panel.
  • Page 10: Incorrect Function

    INCORRECT FUNCTION Incorrects functions is signalled by leds (rep 22) display flashing correspond with chart below. CODE FAULT Overheat sensor switch open. Overheating defect without lock out. No flame detection. Ionisation printed circuit board faulty. Anti-frost mode on (pump in operation). Anti-frost mode on (burner and pump in operation).
  • Page 11: Short List

    SHORT LIST Manf. date Key N° Description G.C N° Manf. Pt. N° Type FF FF FF from 1303566 OVERHEAT THERMOSTAT 105°C 277788 1002801 IGNITION ELECTRODE 277789 1002802 IONIZATION ELECTRODE 277790 1010017 HEAT EXCHANGER E00606 1011136 HEAT EXCHANGER 1304720 FAN ASSY 1304721 FAN ASSY 1306697...
  • Page 12 This appliance is suitable for Natural gas or LPG. A gas conversion must be made by a competent person. Chaffoteaux & Maury are continuously improving their products and therefore reserve the right to change specifications without prior notice and accepts no liability for any errors or omission in the information contained in this document. Manufacturer: Chaffoteaux &...

This manual is also suitable for:

Britony se 80 l.p.g.Britony se 100 l.p.g.

Table of Contents