Bright Adjustment (Vc-242 Board); Contrast Adjustment (Vc-242 Board) - Sony DCR-VX2000 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-VX2000:
Table of Contents

Advertisement

2. Bright Adjustment (VC-242 board)

Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qk of CN007 (EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
95
Specified Value
A = 7.30 ± 0.05V
Adjusting method:
Order Page Address Data
1
0
01
01
2
D
95
3
D
95
4
0
01
00
A
Pedestal
Fig. 5-1-18.
Procedure
Set the data.
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to
the specified value.
Press PAUSE button.
Set the data.
Pedestal
2H

3. Contrast Adjustment (VC-242 board)

Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
D
99
3
D
99
4
0
01
3 steps peak
A
Pedestal
5-31
Camera
Arbitrary
Pin qk of CN007 (EVF VG)
Oscilloscope
D
99
A=2.45 ± 0.05V
Procedure
01
Set the data.
Change the data and set the
voltage (A) between the 3 steps
peak and pedestal to the
specified value.
(The data should be "00" to "7F".)
Press PAUSE button.
00
Set the data.
2H
Fig. 5-1-19.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-vx2000e

Table of Contents