1-1-2.

Preparations

Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-3.
Note 3: As removing the cabinet (R) (removing the VC-242 board CN008)
means removing the lithium 3V power supply (CK-093 board
BT250), data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use (total
drum rotation time etc. ) will be lost. Before removing, note down
the self-diagnosis data and the data on history use (data of page:
2, address: A2 to AA). (Refer to "SELF-DIAGNOSIS
FUNCTION" for the self-diagnosis data, and to "5-4.Service
Mode" for the data on the history use.)
Note 4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (CF-4980) removed. After
completing adjustments, be sure to exit the "Forced Camera
Power ON Mode".
Note 5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Pattern box
Front of the protection glass
5-5
95 cm
Fig. 5-1-2.