11

Wiring Diagrams

Conventional Systems
R
O
B
C
Y1
1st Stage
Compressor
Contact
2nd Stage
Compressor
Contact
NOTE:
1. Transformer Common connection not required for battery-only operation of
thermostat. 2. Eliminate connection to Y2 for units with single stage cooling.

Heat Pump Systems

R
O
B
C
Y1
Changeover
1st Stage
Relay-Cool
Compressor
(See NOTE 4)
Contact
Changeover
Relay-Heat
(See NOTE 4)
NOTE:
1. Transformer Common connection not required for battery-only operation of
thermostat. 2. User installed jumper is required to use auxiliary heat for both second stage
and emergency heat on units without separate emergency heat and auxiliary terminals.
DO NOT install jumper if both terminals are present. 3. Eliminate connection to Y2 for
units with single stage cooling. 4. For units requiring reversing valve to be energized
during heating, connect reversing valve to B terminal. For units requiring reversing valve
to be energized during cooling, connect reversing valve to O terminal.
Y2
E/W1
W2
G
L
1st Stage
Fan Relay
Heat Relay
Auxiliary
System
Heat Relay
Monitor (if
(Stage 2)
equipped)
24 VAC
See
NOTE 2
Y2
E/W1
W2
G
L
Emergency
Fan Relay
Heat Relay
(if equipped)
2nd Stage
Auxiliary
System
Compressor
Heat Relay
Monitor (if
(stage 2)
equipped)
Contact
(See NOTE 3)
24 VAC
20
Premier Series

Programmable Thermostats

LIMITED WARRANTY

Neutral
Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are
due to faulty material or workmanship for a period of five years after the original date of
120 VAC
purchase by a professional service technician. This warranty and our liability does not apply to
Hot
batteries, nor does it include damage to merchandise or the thermostat resulting from
accident, alteration, neglect, misuse, improper installation or any other failure to follow
Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat
under warranty provided it is returned postage prepaid to our warranty facility in a padded
carton within the warranty period, with proof of the original date of purchase and a brief
description of the malfunction. This limited warranty does not include the cost of removal or
re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary from
state to state or province to province. Answers to any questions regarding our limited warranty
may be obtained by writing our corporate offices.
WARRANTY FACILITY: Braeburn Systems LLC
Neutral
120 VAC
Hot
Store this manual for future reference.
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)