Download Print this page

Maintenance Practices - Cirrus SR22 Maintenance Manual

Advertisement

C I R R U S
A I R P L A N E M A I N T E N A N C E M A N U A L

2. MAINTENANCE PRACTICES

A. Oil Filler Cap/Dipstick
For maintenance practices pertinent to the oil filler cap/dipstick, see Scheduled Servicing.
10)
B. Oil Pressure/Temperature Gage - Serials 0002 thru 1601, 1603 thru 1643, 1645 thru 1662
Figure 79-301)
(1)
Removal - Oil Pressure/Temperature Gage
(a)
Set BAT 1, BAT 2, and AVIONICS switches to OFF positions.
(b)
Pull ENGINE INST circuit breaker.
(c)
Remove MFD.
(d)
Disconnect electrical connector from gage.
(e)
Remove screws and washers securing gage to instrument panel. Remove gage from air-
plane.
(2)
Installation - Oil Pressure/Temperature Gage
(a)
Position gage to instrument panel and secure with screws and washers.
(b)
Connect electrical connector to gage.
(c)
Install MFD.
(d)
Reset ENGINE INST circuit breaker.
(e)
Perform Operational Test - Oil Pressure/Temperature Gage.
(f)
Perform Oil Pressure Check as described in airplane Operational Check.
(3)
Operational Test - Oil Pressure/Temperature Gage
(a)
Set BAT 1 switch to ON position.
(b)
Verify oil temperature needle indicates bottom of scale.
(c)
Verify oil pressure needle indicates zero.
(d)
Set BAT 1 switch to OFF position.
79-30
Page 2
15 Apr 2007
(Refer to 31-60)
(Refer to 31-60)
EFFECTIVITY:
All
M O D E L S R 2 2
(Refer to 12-
(See
(Refer to 79-30)
(Refer to 05-30)

Advertisement