Configuring the Printer
3.4.5 Option Horizontal Magnetic Stripe Reader / Writer (MSRW) CONFIGURE
The following items can be modified according to the MSWR parameters.
Note:
You will find the following parameter after the last parameter of OLIVETTI
CONFIGURE
Parameter
END SENTINEL
DISPLACEMENT
POSITION ADJUST
RETRY
STRIPE HANDLE
3-14
.
OPTION HOR. MSRW CONFIGURE
Option
C
F
STANDARD
+10
+20
0
-7 up to +7
1, 3, 5
NORMAL
FAST
Explanation
Selecting the end control of
the magnetic record
Selecting the position
displacement of the
magnetic record.
Select the adjusted value
for the vertical position of
the magnetic record when
reading the magnetic stripe.
S electing the retry value for
reading the magnetic stripe.
Selecting the stripe handle
mode.
NORMAL = measure the
width of a passbook when
reading the magnetic stripe
every time.
FAST = measure the width
of a passbook only one
time. The next reading
procedures are using the
founded width.
Note
Only for PR9/K with
the version 1.07 or
higher.
Only for PR9/K with
the version 1.07 or
higher.
Only for PR9/K with
the version 1.07 or
higher.
Only for PR9/K with
the version 1.07 or
higher.
Only for PR9/K with
the version 1.07 or
higher.