Digital Output
The digital output gives the following functionality:
1. Output Contact
The modem has a change over relay output (SPDT-contact). This output can be  
controlled by a remote modem through Transparent I/O and Output service in the 
Generic I/O function. The output can also be programmed to follow the local DCD  
or DTR signals.
2. Remotely controlled
The output can be programmed to follow a remote modem data input. A remote unit 
can also set/reset the output as well as transferring a sequence of "set- and resets" of 
the output. 
3. Follow DCD/Network
The output can be programmable to follow the local DCD or DTR signal.
Digital Input
The digital input gives the following functionality:
1. Static input
A static digital level trigged input high or low  triggers the Generic I/O. With a level 
trigged input only the first entry in the Generic I/O list can be trigged by the I/O input.
The input is trigged when the selected level has been stable for t a  ms. A new trig will not 
occur until the input has return to the opposite state an back again.
High level trigged input timing
t
a
Trig
Low level trigged input timing
t
a
Trig
6618-2202
≥t
a
≥ t
<t
a
a
t
a
Trig
No trig due to low
level shorter than t
a