VENTING INSTaLLaTIoN
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
G
V
Balcony -
with no side wall
M =
Combustible &
Noncombustible
12" (305 mm)
*NoTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions specified for vinyl or
non-vinyl siding and soffits. 1. There must be a 3' (914 mm) minimum between termination caps. . All mechanical air intakes within 10' (1 m) of a
termination cap must be a minimum of 3' (914 mm) below the termination cap. 3. All gravity air intakes within 3' (914 mm) of a termination cap must
be a minimum of 1' (305 mm) below the termination cap.
Figure 15 -
Termination Clearances
how To uSE ThE VENT GRaPh
The Vent Graph should be read in conjunction with the
following vent installation instructions to determine the
relationship between the vertical and horizontal dimensions
of the vent system.
1. Determine the height of the center of the horizontal vent
pipe exiting through the outer wall. Using this dimen-
sion on the Sidewall Vent Graph below, locate the point
intersecting with the slanted graph line.
. From the point of this intersection, draw a vertical line
to the bottom of the graph.
3. Select the indicated dimension, and position the fire-
place in accordance with same.
Example: If the vertical dimension from the floor of the
fireplace is 11' (3.4 m) the horizontal run to the face of
the outer wall must not exceed 14' (4.3 m).
Example: If the vertical dimension from the floor of the
unit is 7' (.14m), the horizontal run to the face of the
outer wall must not exceed 8Z\x' (.6 m).
Sidewall Vent Graph showing the relationship between
vertical and horizontal dimensions for a Direct Vent flue
system.
53D0419
Outside Corner
G =
Combustible
6" (152 mm)
V
Noncombustible
2" (51 mm)
Balcony -
with perpendicular side wall
M
M
V
Combustible &
Noncombustible
M = 12" (305 mm)
P = 6" (152 mm)
Alcove Applications*
F =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
F
V
P
D
C
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
20"
2
Horizontal Dimension From the Outside Face of the
Wall to the Center of the Fireplace Vent Flange
Figure 16 -
Rear Wall Venting Graph
FP2248
sidewall vent graph
Designer Series Gas Fireplaces
D
C
C
V
E
O
E
= Min. 2" (51 mm) for
non-vinyl sidewalls
Min. 12" (305 mm) for
vinyl sidewalls
O
= 8' (2.4 m) Min.
No.
of Caps
D
Min.
1
3' (914 mm) x D
6' (1.8 m)
1 x D
3
9' (.7 m)
/3 x D
4
1' (3.7 m)
1/ x D
= # of Termination caps x 3
Min.
= ( / # termination caps) x D
Max.
Dimensions in
Feet
eg: A
2 4 6 8 10 12 1 4 16 18 2 0
C
Max.
Actual
Actual
Actual
Actual
Actual
15