How To Use The Vent Graph - Majestic DVBL7 Series Installation And Operating Instructions Manual

Direct vent
Table of Contents

Advertisement

DVBL7 Series Gas Fireplace
t-LoCK PIPeS
When using unitized T-Lock pipe it is not necessary to
use sealant on the joints. The only areas of the venting
system that need to be sealed with high temperature sili-
cone sealant are the sliding joints of any telescope vent
sections used in the system.
To join T-Lock pipes together, simply align both inner and
outer pipes with the next section. Align the internal beads
of the female end with the T-channels of the male end.
Figure 9
Internal
Beads
f i r e - p a r t s . c o m
Female End
Figure 14 -
T-Lock Pipe Joints
Insert male end until beads on the female end contact
FP2740
bottom of T-channel on male end. Twist pipe until beads
stop at ends of T-channel.
T lock channels
IMPortaNt: Pipe can be twisted in either direction.
however, aLL PIPe SeCtIoNS MuSt Be rotateD IN
the SaMe DIreCtIoN.
Securing the joints with sheet metal screws is not re-
quired.
To
disassemble
T-Lock pipe, ro-
tate
pipe
sec-
tions until internal
beads on female
end
align
with
diamond
inden-
tations on male
end. Figure 9a.
Pipe sections will
then easily sepa-
rate
by
pulling
Figure 14a -
straight apart.
T-Lock Disassemble
14
T-Channel
Arrow
Indentations
FP2740
Male End
Female End
Arrow
Indentations
on Male End
FP2741
FP2741
T-lock undo
VeNtING INStaLLatIoN INForMatIoN

how to uSe the VeNt GraPh

The Vent Graph should be read in conjunction with the
following vent installation instructions to determine the re-
lationship between the vertical and horizontal dimensions
of the vent system.
1. Determine the height of the center of the horizontal
vent pipe exiting through the outer wall. Using this di-
mension on the Sidewall Vent Graph, Figure 10, locate
the point intersecting with the slanted graph line.
2. From the point of this intersection, draw a vertical line
to the bottom of the graph.
3. Select the indicated dimension, and position the fire-
place in accordance with same.
exaMPLe a:
If the vertical dimension from the floor of the unit is 11' (3.4
m) the horizontal run to the face of the outer wall must not
exceed 14' (4.3 m).
exaMPLe B:
If the vertical dimension from the floor of the unit is 7' (2.1
m), the horizontal run to the face of the outer wall must not
exceed 7' (2.1 m).
refer to Page 18 for requirements for snorkels.
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
57" from
8
floor to
6
center
4
2
2    4    6   8  10  12 14  16 18  20
Horizontal dimension from the finished outside wall
to the center of the pipe on the fireplace
Figure 10 -
Rear Wall Venting Graph
FP2337
sidewall vent graph
eg: a
eg: B