Specifications - IBC DC 23-84 Installation And Operating Instructions Manual

Dc series combi boiler
Table of Contents

Advertisement

SPECIFICATION
CSA Input (Natural Gas or Propane) – MBH
CSA Input (Natural Gas or Propane) – KW
CSA Output – MBH
CSA Output - KW
DHW - CSA Input (Natural Gas or Propane) - MBH
DHW - CSA Input (Natural Gas or Propane) - KW
A.F.U.E
Min Gas Pressure (Nat. Gas or Propane) – inch w.c.
Max Gas Pressure (Nat. Gas or Propane) – inch w.c.
Power (120Vac/60Hz) - Watts @ full fire with internal pump
Weight (empty) – lbs/Kg
Pressure Vessel water content – USG/Liters
Max boiler flow rate - USgpm
Min boiler flow rate - USgpm
Max Operating Pressure – Space Heating Coil - psig
Max Operating Pressure – Domestic Hot Water Coil - psig
Approved installation altitude - ASL
Ambient Temperature – Low (°F/°C)
Ambient Temperature – High (°F/°C)
Max relative humidity (non-condensing)
Min water Temperature - Space Heating (°F/°C)
Max water Temperature – Space Heating (°F/°C)
Min water Temperature – Domestic Hot Water (°F/°C)
Max water Temperature – Domestic Hot Water (°F/°C)
Min flow rate to activate DHW heating - USgpm
Max flow rate DHW heating - USgpm
Max equivalent vent length 3" (each side)
Max equivalent vent length 2" (each side)
* Natural Gas boilers require a Propane conversion kit (see page #3-2, Table 10) to be ordered separately if converting a Natural Gas boiler to Propane. Propane (LP)
boilers require a Natural Gas conversion kit (see page #3-2, Table 10) to be ordered separately if converting a Propane boiler to Natural Gas.
† boilers are shipped with 30 psig pressure relief valve
INSTALLATION AND OPERATING INSTRUCTIONS
DC SERIES COMBI BOILERS DC 23-84, DC 29-106, DC 33-124, DC 33-160

SPECIFICATIONS

DC 23-84
DC 29-106
23 – 84
28.5 – 106
6.7 – 24.9
8.4 – 31.0
21 – 79
26 – 99
6.3 – 23.0
7.8 – 28.9
23 - 84
28.5 - 106
6.7 - 24.9
8.4 - 31.0
94%
94%
5
5
14
14
126
128
85 / 39
85 / 39
0.37/1.4
0.37/1.4
9
10
2
3
43.5
43.5
150
150
12,000 ft
12,000 ft
32/0
32/0
122/50
122/50
90%
90%
15/20
15/20
194/90
194/90
104/40
104/40
149/65
149/65
0.5
0.5
2.6
3.3
120'
120'
35'
35'
DC 33-124
DC 33-160
33 – 124
33 – 160
9.7 – 36.3
9.7 – 46.9
31 – 115
30 – 149
9.0 – 33.8
9.0 – 43.6
33 - 124
33 - 124
9.7 - 36.3
9.7 - 36.3
94%
94%
5
5
14
14
130
164
85 / 39
85 / 39
0.5/1.9
0.5/1.9
11
11
3
3
43.5
43.5
150
150
12,000 ft
12,000 ft
32/0
32/0
122/50
122/50
90%
90%
15/20
15/20
194/90
194/90
104/40
104/40
149/65
149/65
0.5
0.5
4.0
4.0
120'
120'
35'
35'
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc 29-106Dc 33-124Dc 33-160Hc 13-50

Table of Contents