Safety Considerations; Specifications - IBC VFC 15-150 Manual

Modulating gas boilers natural gas or propane
Table of Contents

Advertisement

WARNING
If the information in this
manual is not followed
exactly, a fire or explosion
may result causing property
damage, personal injury, or
loss of life.
HAZARDS &
PRECAUTIONS
DANGER
Points out an immediately
hazardous situation which
must be avoided in order
to prevent serious injury or
death.
WARNING
Points out a potentially
hazardous situation which
must be avoided to prevent
serious injury or death.
CAUTION
Points out a potentially
hazardous situation which
must be avoided to prevent
possible moderate injury and/
or property damage
NOTE
Points out installation,
maintenance and operation
details that will result in
enhanced efficiency, longevity
and proper operation of your
boiler.
VFC 15-150 - VFC 45-225 MODULATING GAS BOILERS

SAFETY CONSIDERATIONS

Installation, start-up and servicing of IBC boilers must be done with due
care and attention, and should only be performed by competent, qualified,
licensed and trained heating technicians.
Failure to read and comply with all instructions and applicable National and
local codes may result in hazardous conditions that could result in prop-
erty damage and injury to occupants which in extreme cases might result
in death.

SPECIFICATIONS

SPECIFICATION
CSA Input (Natural Gas or Propane) - MBH
CSA Input (Natural Gas or Propane) - kW
CSA Output - MBH
CSA Output - kW
A.F.U.E.
Minimum gas supply pressure (Natural Gas or Propane) - inch
w.c.
Maximum gas supply pressure (Natural Gas or Propane) - inch
w.c.
Power use (120Vac/60Hz) @ full fire - Watts (excluding pumps)
Weight (shipping) - lbs/Kg
Pressure vessel water content - USG/Litres
Maximum boiler flow rate - USgpm
Minimum boiler flow rate - USgpm
Maximum operating water pressure* - psig
Minimum water pressure - psig
Normal flue temperature @ 100°F boiler return water temperature
- high fire
Normal flue temperature @ 160°F boiler return water temperature
- high fire
Approved installation altitude - ASL
Ambient temperature - Low (°F-°C)
Ambient temperature - High (°F-°C)
Max. relative humidity (non-condensing)
Minimum water temp.
Maximum water temp. (electronic hi-limit)
Maximum water temp. (mechanical hi-limit)
Max. ΔT - supply/return (electronic fence)
Maximum equivalent vent length
Each side (Vent & Air Intake))
(Natural Gas or Propane)
Air intake options: either direct vent or indoor supply
* boilers are shipped with 30 psig pressure relief valve - up to 75 psig relief valve can be ordered
Supplied with the boiler - the iBC boiler is shipped with an accessory parts kit
consisting of the following items:
• 1 x Vent connection kit
• 1 x Condensate trap kit
• 1 x 30 psig pressure relief valve (higher pressure 75 psig - by special order).
• 1 x outdoor temperature sensor
VFC 15-150 VFC 45-225
- 2"
- 2 1/2"
- 3"
INSTALLATION AND OPERATION INSTRUCTIONS
15 - 150
45 - 225
4.4 - 44
13 - 66
14 - 139
41 - 206
4.1 - 41
12 - 60
96.1%
96.1%
3
3
14
14
14
14
57
158
165 / 75
168 / 76
2.4 / 9
2.4 / 9
16
25
4
80
80
8
100 to 105 °F
100 to 105 °F
37.8 to 40.5°C
37.8 to 40.5°C
160 to 165 °F
160 to 165 °F
71.1 to 73.9°C
71.1 to 73.9°C
0 - 8,000'
0 - 8000'
32°F / 0°C
32°F / 0°C
122°F / 50°C
122°F / 50°C
90%
90%
34°F / 1.1°C
34°F / 1.1°C
190°F / 87.8°C
190°F / 87.8°C
200°F / 93.3°C
200°F / 93.3°C
35°F
35°F
50'
n/a
70'
n/a
120'
240'
3
3
8
8