External Trigger Shutter - Sony XC-ST50 Technical Manual

B/w video camera module
Hide thumbs Also See for XC-ST50:
Table of Contents

Advertisement

XC-ST50/50CE
XC-ST30/30CE
ELECTRONIC SHUTTER

External trigger shutter

By inputting an external trigger, the image of a high-speed moving object can be captured in an exact position.
Set DIP switches 6, 7, and 8 on the rear panel to mode 1 or 2. (Refer to the table below.)
When the trigger pulse width is 1/3 sec or more, the camera switches to normal (continuous) video operation.
There are two modes for timing in which a video signal is obtained.
• Mode 1 (Non-reset mode)
In this mode, an output video signal is synchronized with the VD signal after the triggered exposure is
complete.
An output video signal synchronized with the external VD signal when an external HD/VD signal is input.
An output video signal synchronized with an internal VD signal when no external HD/VD signal is input.
• Mode 2 (Reset mode)
In this mode, a video signal is output soon after exposure is complete.
For more details of each timing chart, refer to pages 16 to 23.
*
Setting of external trigger shutter speed
There are two ways to set the shutter speed.
• Using DIP switch on the rear panel
Mode 1 (Non-reset mode)
Switch
*
1/100
1/125
1
2
3
4
1
5
6
0
7
1
8
1
Mode 2 (Reset mode)
*
1/100
1/125
Switch
1
2
3
1
4
5
6
0
7
0
1
8
• Using trigger pulse width
Set all DIP switches 1 to 4 on the rear panel to 0.
An arbitrary shutter speed can be obtained by setting the trigger pulse width to the range of 2 µsec to 250
msec.
Mode 1
Switch
(Non-reset mode)
0
1
0
2
3
0
0
4
5
Frame: 0 / Field: 1
0
6
1
7
8
1
8
1/250
1/500
1/1000
1
0
1
0
0
1
1
0
0
0
0
1
0
0
0
0
Frame: 0 / Field: 1
0
0
0
0
1
1
1
1
1
1
1
1
1/250
1/500
1/1000
1
0
1
0
0
1
1
0
0
0
0
1
0
0
0
0
Frame: 0 / Field: 1
0
0
0
0
0
0
0
0
1
1
1
1
Exposure time = Trigger pulse width + 97 µsec (XC-ST50/ST30)
Mode 2
(Reset mode)
0
0
Note
0
0
0
0
1: ON
1
0: OFF
1/2000
1/4000
**
1/10000
1
0
1
0
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
1/2000
1/4000
**
1/10000
1
0
1
0
1
1
1
1
1
0
0
0
6
0
0
0
0
0
0
1
1
1
: 1. lt is recommended to set DIP switch 5 for field selection.
(The field selection is about two times higher sensitivity than frame selection.)
2. After a trigger pulse is input, a new trigger pulse should not be input before the video
signal obtained by the trigger pulse has been output.
*
The external trigger shutter speed is set to
1/100 sec for XC-ST50/ST30(EIA) and 1/120
sec for XC-ST50CE/30CE(CCIR).
**
The external trigger shutter speed is set to
1/10000 sec for XC-ST50/ST30(EIA) and
1/8000 sec for XC-ST50CE/30CE(CCIR).
1: ON
0: OFF
–: Either ON or OFF
120 µsec (XC-ST50CE/ST30CE)