Foreign Configuration Disk Appears In The Windows Gui After Booting - Bosch DIP-7080-00N Installation Manual

Divar ip 7000 2u
Hide thumbs Also See for DIP-7080-00N:
Table of Contents

Advertisement

54
en | Recovering the unit
6.2.3

Foreign configuration disk appears in the Windows GUI after booting

The RAID is degraded. Topology error is shown. Right-click Megaraid Controller in the MSM
GUI. Click "scan foreign configuration". In the next window, click "clear foreign configuration".
An unconfigured good drive is displayed. Right-click this drive and choose a hotspare type.
You see the rebuild is starting at once.
2013.09 | V2 | DOC
Installation Manual
DIVAR IP 7000 2U
Bosch Sicherheitssysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dip-7082-8hd

Table of Contents