Available languages

Switch off unit and release the pressure in the unit
when working on the high-pressure filter.
Attention:
Never unscrew the filter housing (fig. 2, item 1)
while still under pressure if the high pressure filter is
blocked. Correct procedure:
1. Switch off unit.
2. Remove mains plug from the socket.
3. Release the safety unit on the spray gun and
open trigger.
4. Open release tap (2) – lever relocated.
5. Unscrew the filter housing.
6. Clean or replace filter insert.