QUICK START GUIDE
This guide provides the basic information you
need to set up and begin using your new
FlexPak-G2. For more detailed information on
the installation and operation of your receiver,
please refer to the user manuals provided on
the accompanying CD. The most up to date
revisions of these manuals can be found on our website at
www.novatel.com/Downloads/docupdates.html. To order a
printed copy of the manuals, free of charge, follow the
instructions given on the enclosed User Manuals postcard.
The FlexPak-G2 provides a Mini-B USB connection. The USB
drivers, along with installation instructions, are available in the
USB Driver's directory of the CD provided. An installation
program for NovAtel's PC Utilities, including the CDU (Control
and Display Unit) user interface, and sample source code, are
also on the CD.
Each FlexPak-G2 receiver tracks a different satellite
combination, as follows:
FlexPak-G2-OEMStar: Single frequency GPS +
GLONASS + SBAS
FlexPak-G2-V1: Single frequency GPS + SBAS +
OMNISTAR VBS + CDGPS
FlexPak-G2-V1G: Single frequency GPS + GLONASS +
SBAS
FlexPak-G2-V2: Dual frequency GPS + GLONASS +
SBAS
BOX CONTENTS
In addition to this Quick Start Guide, the following is provided
with your FlexPak-G2:
1 power adapter cable
1 null modem serial cable
1 USB cable
1 I/O cable
1 CD containing:
NovAtel's PC Utilities' installation program
Product documentation, including user manuals
Sample source code
Quick Reference Guide
User Manuals postcard for requesting printed manuals
ADDITIONAL EQUIPMENT REQUIRED
http://
The additional equipment listed below is required for a typical
setup:
A Windows-based PC with an RS-232 DB-9 or USB port
One of the following:
A standard 12 V DC power outlet, or
Power cable supplied with LEMO connector and
6-18 V DC power supply, 750 mA.
If you use an alternative power source, a 12V car adapter can
be cut off from the power cable.The exposed wires can then be
tied to a 6-18Vsupply capable of at least 5 W.
Since the 12V car adaptor on the supplied adaptor cable
incorporates a 6A fuse, a user supplied 6A slow blow fuse in a
suitable holder must be used at the alternate power source to
protect both the power supply and your warranty.
See Step 4, in Setting Up Your FlexPak-G2, for an illustration of
this process.
A quality GNSS antenna, such as one from NovAtel's
700 or ANT series. Contact your NovAtel representative
for a full range of options.
An antenna cable with a TNC male connector at the
receiver end, such as NovAtel's GPS-C016 model
SETTING UP YOUR FLEXPAK-G2
Complete these steps to connect and power your FlexPak-G2.
1. Mount an antenna on a secure, stable structure with an
unobstructed view of the sky.
2. Using a coaxial cable, connect the antenna to the
port, which is found on the front face of the FlexPak.
3. Connect the COM1 or USB port on the receiver to the USB
or serial port on the PC. If you are using a USB connection,
install the USB drivers available on the CD provided.
4. Connect the power cable connector to the PWR port. Line
up the red mark on one power cable connector with the red
mark on the receiver's PWR port and insert power cable.
:
For an alternative power source
a) Cut a 12V car adapter from the power cable.
b) Tie the exposed wires to a 6-18V supply capable of at least 5 W.
*Be sure to connect the red and orange wires to the
positive side of supply and connect the black and brown
wires to the negative side of supply.
c) Use a user supplied 6A slow blow fuse at the alternate power
source to protect the power supply wiring and your warranty.
Fuse/Holder Recommentations:
12V Systems
LITTELFUSE "ATO" 0257005 Fuse (or equivalent)
LITTELFUSE "MINI" 0297005 Fuse (or equivalent)
Holders
ATO/TAC ATO: LITTELFUSE FHAC0001 (or equivalent)
MINI: LITTELFUSE 0FHM0001 (or equivalent)
6A Fast Blow Fuse
(User Supplied)
+
-

Advertisement

loading

Summary of Contents for Novatel FlexPak-G2-V1

  • Page 1 3. Connect the COM1 or USB port on the receiver to the USB b) Tie the exposed wires to a 6-18V supply capable of at least 5 W. program for NovAtel’s PC Utilities, including the CDU (Control • Power cable supplied with LEMO connector and or serial port on the PC.
  • Page 2 2. Insert the accompanying CD in the CD-ROM drive of the computer. As CDU establishes the communication session with the 3. Select Install NovAtel’s PC Utilities from the window that is 4. Enter a name for the new device configuration in the Name receiver, a progress box is displayed.
  • Page 3 FlexPak-G2 models are also capable of SBAS positioning. This Refer to the OEMV Family Firmware Reference Manual for more on individual L-Band (FlexPak-G2-V1 only), GLONASS (FlexPak- positioning mode is enabled using the SBASCONTROL command. G2-V1G or FlexPak-G2-V2) or SBAS commands and logs.
  • Page 4 10 1 (optional) A data link is needed between the base station and rover station Rover (two NovAtel receivers) in order for the rover to receive interfacemode com2 rtca none off corrections. The data link must support the throughput needed to receive complete correction messages.

This manual is also suitable for:

Flexpak-g2-v1gFlexpak-g2-v2Flexpak-g2-oemstar