SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
Slideout manufacturer's user guide in your
InfoCase to determine the problem. The error
code must be cleared prior to operating the room.
Further Information
See the In Wall slideout room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT ROOM
TROUBLESHOOTING (POWER
GEAR
) UNDER FLOOR
®
SLIDEOUT
–If Equipped
Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
Turn the Chassis Battery Disconnect switch
OFF and then ON again. This will, in many
cases, reset power to the slideout system.
he chassis battery may be low on charge.
Press and Hold the Battery Boost switch
(located on the dash) while pressing the
interior slideout control switch. This
momentarily connects the house batteries to
assist in slideout room operation.
The circuit breaker may be tripped. The
circuit breaker, labeled "Slideout Power" is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
Problems Retracting the Room
Set the Park Brake if the Engage Park Brake
light flashes while pressing the Retract (IN)
button.
10-6
• Light will flash if
park brake not set
• Low Voltage
Indicator
Slideout Touchpad
(Located in cabinet above main
entrance door or near systems monitor
panel depending on model)
-Typical View
If an error is detected on your slide system, the
LED light on the control panel will blink an error
code. If an error code appears, see the
manufacturer's user guide in your InfoCase to
determine the problem. The error code must be
cleared prior to operating the room. To clear the
error and reset the system:
If none of the "Battery Voltage or Circuit
Breaker Problems" troubleshooting
recommendations reset the system, remove
the touchpad from the monitor panel (a
screwdriver will be needed) and press and
hold the RESET button ("Set Stops/Clear
Fault") located on the back of the touchpad for
5 seconds. The slideout is now ready to be
retracted. Press IN on the touchpad to retract
the room.
Reinstall touchpad to the wall.
Take your vehicle to an authorized service
center for repair.
Before operating the room after an error has
been detected, check for obvious faults such as
obstructions prior to trying to operate the room
again. If the error code appears again, the room
will need to be retracted using either the manual
retraction method or the fully manual method.