12. Fresh water system
State of Play is equipped with two water tanks with a capacity of 210 gallons
split between the two.
Before filling the tanks let the water run from the hose for a while before
placing the end into the filler.
locker and at the port transom. Please ensure that the correct fillers are
used, NOT the holding tanks or the diesel fill.
To use the fresh water system, turn on the fresh water breaker on the 12v
panel and open a faucet. When the tank runs out of water the pump will run
at high speed and the faucet will start to cough air. As soon as you hear the
pump running continuously, check to see if anyone is using water. If not,
switch off the pump immediately to prevent the pump from drawing more air
into the system or the pump overheating.
To switch tanks:
Switch off pump
Select the next full tank: the lever is located beneath the sink in the aft
port head.
The lever is not 'on' or 'off' – it has two positions (horizontal and vertical)
that select one or other tank. After selecting required tank:
Switch on pump.
Open cold water faucet at galley and purge system of air, approx. 45
seconds
Turn off faucet, pump will continue to run until adequate pressure has
built up to operate pressure switch to cut the pump out.
If pump does not cut out, it may be necessary to repeat the purging
process and open other faucets
If you have any problems, call Horizon.
The filler holes are located by the anchor