Precautions For Wireless Remote Controller Installation And Operation - Mitsubishi Daiya SRK50HA User Manual

Wall mounted type room air-conditioner, split system, air to air heat pump type
Table of Contents

Advertisement

Item
High pressure MPa(kgf/cm
Low pressure MPa(kgf/cm
Temp. difference between
suction air and discharge air (˚C)
Running current (A)
(b) Cooling only type
Model
Item
High pressure MPa(kgf/cm
Low pressure MPa(kgf/cm
Temp. difference between
suction air and discharge air (˚C)
Running current (A)
Note (1) The data are measured at following conditions.
Ambient air temperature
Indoor side: Cooling ... 27°C DB, 19°C WB, Heating ... 20°C DB
Outdoor side: Cooling ... 35°C DB, 24°C WB, Heating ... 7°C DB, 6°C WB
1.5.6

Precautions for wireless remote controller installation and operation

(1) Wireless remote controller covers the following distances:
(a) When operating facing the air-conditioner:
Wireless remote
controller
5 m or less
(b) When manipulating the remote controller mounted on a wall:
Make sure that it works normally (i.e., transmission/reception signal is
audible) before mounting.
32
Model
Cooling
2
)
Heating
Cooling
2
)
Heating
Cooling
Heating
Cooling
Heating
SRK50CA
2
)
2
)
0.39 ~ 0.49 (4 ~ 5)
12 ~ 16
8.4/8.0/7.7
or less
SRK50HA
1.86 ~ 2.06 (19~21)
0.39 ~ 0.49 (4 ~ 5)
12 ~ 16
19 ~ 23
8.4/8.0/7.7
8.5/8.1/7.9
Notes (1) The remote controller is correctly facing the sensing
element of the air conditioner when being manipulated.
(2) The typical coverage is indicated (in the left illustration).
It may be more or less depending on the installation.
(3) The coverage may be less or even nil. If the sensing
element is exposed to strong light, such as direct
sunlight, illumination, etc., or dust is deposited on it or
it is used behind a curtain, etc.
Receiver
(220/230/240V)
SRK56HA
1.86 ~ 2.06 (19~21)
0.34 ~0.44 (3.5 ~ 4.5)
12 ~ 16
21 ~ 25
9.7/9.3/8.9
9.8/9.4/9.0
(220/230/240V)
SRK56CA
0.34 ~ 0.44 (3.5 ~ 4.5)
12 ~ 16
9.7/9.3/8.9
Remote control
available in this area.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk56haSrk408henf-l3

Table of Contents