Page 22
COOL/DRY/FAN mode operation procedure R 25R 1 R 25R 1 R 35R 1 R 35R 1 R 50R 1 R 50R 1 ECONO operation procedure How to set the Installation site How to set the Child Lock The following situations is not a failure Has the unit been installed correctly? RYD012A352 RYD012A352...
Page 24
Page9 Page9 FAN SPEED Page9 You can set your fa- vorite wind AUTO/ HI/ MED/LO/JET Mdirection as you need. Page12 Page 12、13 Page15 Page10 RYD012A352...
COOL/DRY/FAN mode operation procedure Aim the remote control at the air conditioner. Press the button. AREA Press this button to set the air- conditioning area in the room. Press the button. The screen is switched as shown below. COOL, DRY, FAN Page12 / ECO Select the desired operating mode...
Page 27
Air flow direction adjustment procedure SLEEP operation procedure Aim the remote control at the air conditioner. The machine will stop automatically when reaching the set time. To control the indoor temperature not cold during COOL, and to control the indoor temper- Press the button.
Page 28
ON-TIMER operation procedure OFF-TIMER operation procedure The unit stops automatically at the end of the set period of time. When the current status If the room temperature is at near optimum temperature at the set time, the operation starts of the air conditioner in stop, start from Procedure l, if it is under operation status, start fr- 5 to 60 minutes before the set times.
Page 29
Setting method of the current time "SLEEP" operation+"ON-TIMER" operation procedure The current time will be set to 13:00 auto matically after the battery is installed. When en- Joint operation of the “SLEEP”function and “ON-TIMER”function. tering in the time setting,all the contents on the remote controller will be reset. Example:If you wish it to stop after 3 hours, start operation Example: it is set to 10:30.
HI POWER operation procedure ECONO operation procedure When the room does not want to be too cold, it can control the ability to operate in a Concerning high power operation comfortable mode. Pressing the button intensifies the operating power and initiates a powerful If the air conditioner is not running.
Operation methods of regional settings How to set the Installation site You can regulate the indoor air and the air in the specific area by the regional setting You should consider the installation site of air conditioner in order to adjust the air flow function.
How to set the Child Lock Emergency run operation procedure Child lock is set to prevent misuse, which can be made under the ON/OFF state. The “ON/OFF” button on the unit operates “ON/OFF” temporarily when the remote con- trol is not used. Make a long press of button for more than 3 seconds.
Page 33
Remote control handing procedure When the operation fails with the remote control Replacing the batteries Are the batteries running down? If the operation still fails, handle as per Page21 Replace the batteries with new emergency run operation. Contact your The following cases signify exhausted batteries.replace old batteries with new ones. ones and repeat the operation.
Page 34
Maintenance At the beginning of the season At the end of the season Make certain that there are no obstac- Set the temperature setting for app- During the operational season Before maintenance roximately a half day at 30℃ and les blocking the air flow around the air intake and outlet openings of the ind- perform the cooling operation.
Installation, inspection and change of the filter screen Installation, inspection and change of the filter screen The air filters clogged with dust, etc., then the cooling / heating capacity will How to open the air inlet panel How to close the air inlet panel drop, the operation noise increases, power consumption also increases.
The following situation is not a failure Has the unit been installed correctly? Suitable installation position The memory circuit of the microcomputer has After a power cut, you cannot restart, been wiped out. Use the remote control to sta- even if power has been restored. rt the operation again.
Page 37
Troubleshooting Self diagnosis function Please carry out the following checks before making a service call. The company always strives to provide the clients with more excellent service and install different judgment systems to display the following abnormal functions (the ones for abn- The air conditioner does not work at all ormal lighting and quenching type are illustrated as follows.
Page 38
Sheet, installation Please read these “safety Precautions” first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, Accessorles list Installation tool (necessary) those points which are related to the strong possibility of an installation done in error resulting in or senous injury are listed in the section.However, there is also a possibility of serious consequences in relationship to the points listed in the...
Page 39
Model specification specification current SRK25RE1 The exhaust port and inspiration port behind the equipment shall be installed 10cm far SRK35RE1 away from the wall. (If the height of the fence is higher than 1.2m ar above the head, suf- ficient space shall be left between the equipment and the wall.
Page 40
Find the stent, small column and other structural parts of 106.5 106.5 171.5 171.5 the wall first install and filx more firmly after making en- sure whether the installation place is horizontal. Four screws are used to hor- The center of circle levels with izontally adjust the installati- datum line of installation board on board when it is under the...
Page 42
Limit of the size and length of the Liquid piping(mm) 6.35×0.8 6.35×0.8 6.35×0.8 Gas piping(mm) 9.52×0.8 9.52×0.8 12.7×0.8 50 50 Please notice,when using R410A professional flaring too or common flaring tool, that size B (from the outstanding part of the flaring board) will change, which is determined by the type of the flaring tools.
Page 43
The safety and comfort life period of the product is ten years. Some products also can be used after the life period. After the life period, deal of the rejectamenta, must consider the effet of the safety and the en- vironment.