1.3 ELECTRICAL DATA

1.3.1 Electrical wiring

Models SRK50HA, 56HA
Power source
1 Phase 220/230/240V 50Hz
Y/GN
BL
BR
Y/GN
52C-4
G
52C-3 S
52C
BL
5
Y
F
4
(
)
250V
WH
FM
3
3.15A
I
BK
2
RD
1
CNU
CNM
LM
Printed circuit board
Color symbol
BK
Black
BL
Blue
BR
Brown
RD
Red
OR
Orange
WH
White
Y
Yellow
Y/GN
Yellow/Green
Meaning of marks
Symbol
C
Capacitor for CM
C
CF
Capacitor for FM
O
CM
Compressor motor
F
Fuse
FM
Fan motor (Indoor unit)
I
FM
Fan motor (Outdoor unit)
O
LM
Louver motor
PC
Photo coupler
Table of relay operations
Operation
Relay symbol
Control part
52X
20S
1
52X
A
FM
52X
B
52C
CM
; denotes magentized relay ×: denotes demagnetized relay
Notes (1)
(2) Th
is room temperature thermistor. Th
1
(for details, refer to pages 19, 20, 22)
(3) Preset values :
23DH (defroster stop thermostat) : opens at over 14˚C
63H (overload protection high pressure switch during heating) : closes at 1.86(19.0 )/ opens at 2.41(24.5) [MPa(kgf/cm
12
Indoor unit
OR
RD
WH
BK
20S
23D
52C
PC
52X
1
52X1
ZNR
Parts name
Symbol
O
52X
Cooling
Heating
×
×
×
×
O
(the heat exchanger thermistor) is the hot start, hot keep, and frost prevention thermistor.
2
Outdoor unit
RD
4
4
BL
3
3
WH
2
2
BK
1
1
52X
TH
1
TH
2
Wireless
R-Amp
Display
Back up sw
Note(1) This figure shows SRK56HA. As for
Parts name
Th
Thermistor
1, 2
ZNR
Varistor
20S
4 way valve. coil
51C
Motor protector for CM
52C
Magnetic contactor for CM
Auxiliary relay
A, B, 1
63H
High pressure switch
23DH
Thermostat (Defrost)
Defrost
×
×
RD
RD 63H
RD
RD
BK
A
23
DH
52X
B
BL
BK
OR
FM0
20S
52X
A
52X
CF
B
0
SRK50HA, 51C differs as shown in the fig-
ure below.
51C
2
)]
51C
CM