Mitsubishi Daiya SRK50HA User Manual page 21

Wall mounted type room air-conditioner, split system, air to air heat pump type
Table of Contents

Advertisement

(11) DRY operation
(a) Choose the appropriate operation block area by the difference between room temperature and thermo-
stat setting temperature as shown below.
¡Operation block area
D Block
Room temp. – Setting temp.(deg)
(b) Start up operation
C.D Block
ON
Compressor
and
OFF
outdoor fan
Set fan speed
Speed 1
Indoor fan
OFF
0
Start
Note (1)
Thermostat operation is performed in A, B Block. When compressor and indoor fan stop by thermostat operation within 12 minutes from start, temperature
check is performed by operating indoor fan at speed 1 for 20 seconds before finishing 12 minutes and allowing decision of next operation block.
(c) DRY operation
After finishing start up operation described in (b) above, thermal dry operation is performed at 8 minutes intervals, according
to the difference between room temperature and thermostat setting temperature as shown below.
Beside, 1 cycle of this operating time consists of 8 minutes, 7 cycle operation is performed then.
Compressor
and
OFF
outdoor fan
Speed 1
Indoor fan
OFF
0
Start
B Block
Compressor
ON
and
OFF
outdoor fan
Speed 1
Indoor fan
OFF
0
Start
C Block
B Block
–2
0
+3
6
3
9
12
Temperature check
D Block
20 seconds
8
minutes
Temperature check
20 seconds
8
4
minutes
Temperature check
A Block
A.B Block
Compressor
ON
and
OFF
outdoor fan
Set fan speed
Speed 1
Indoor fan
20
OFF
seconds
minutes
0
Start
Operation block decision
C Block
Compressor
ON
and
OFF
outdoor fan
Speed 1
Indoor fan
OFF
0
Start
Operation block decision
A Block
Compressor
ON
and
OFF
outdoor fan
Speed 1
Indoor fan
OFF
Start
Operation block decision
Temperature check
20 seconds
8
3
Temperature check
0
Temperature check
12
minutes
minutes
8
minutes
21