Model SRK56A (Indoor unit)
SRC56HA (Outdoor unit)
Item
(1)
Cooling capacity
(1)
Heating capacity
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP (In cooling)
Sound level
Cooling
Power level
Noise level
Sound level
Heating
Power level
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(3)
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
(Cooling)
(Heating)
Air filter, Q'ty
Shock & vibration absorber
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) The operation data are applied to the 220V, 230V or 240V districts respectively
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping. (Purging is not required even in the short piping.)
If the piping length is longer. (When it is 7 to 15 m, add 20 g refrigerant per meter.)
(4) When the unit is operated in cooling or dehumidification mode at the outside air temperature of 1ºC and less, there is a possibility that water leakage
occurs at the indoor unit.
Model
SRK56A
W
W
kW
A
kW
A
A
Hi : 45
Hi : 59
dB
Hi : 45
Hi : 59
mm
298‚798‚203
Stucco white
kg
10
kW
kg
R
Tangential fan x 1
W
23
11
CMM
13
Polypropylene net (washable) x 2
Wireless–Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
mm(in)
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Liquid line: 0.5m Gas line: 0.43m
Indoor air temperature
DB
WB
27ºC
19ºC
20ºC
5000
6200
1 Phase, 220/230/240V, 50Hz
2.08
9.7/9.3/8.9
2.10
9.8/9.4/9.0
44/46/48
2.40
Lo : 38
Lo : 52
Lo : 38
Lo : 52
RM5526GNE4 (Rotary type) x 1
Louver fins & grooved tubing
Capillary tubes
R22 1.45
0.7 (BARREL FREEZE 32SAM)
MC control
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Flare connecting
Necessary (Both sides)
Connectable
3m (3 cores with Earth)
1.5mm
2
x 5 cores (With Earth)
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
DB
WB
35ºC
24ºC
7ºC
6ºC
SRC56HA
51
65
53
67
640‚850‚290
Stucco white
45
1.9
Line starting
Propeller fan x 1
35
39
39
Standards
ISO-T1, JIS C9612
ISO-T1, JIS C9612
5