Serial/Model Number/Replacement Parts - Modine Manufacturing HD Series Installation And Service Manual

Gas-fired unit heaters
Hide thumbs Also See for HD Series:
Table of Contents

Advertisement

serIAl & model numBer / replACemenT pArTs
model number designations
HD
HD - Tubular Power Vented
Propeller Unit
HDB - Tubular Power
Vented Blower Unit
MBH Input
30 - 30,000 Btu/hr input
45 - 45,000 Btu/hr input
60 - 60,000 Btu/hr input
75 - 75,000 Btu/hr input
100 - 100,000 Btu/hr input
125 - 125,000 Btu/hr input
Heat Exchanger Type
A - Aluminized
S - Stainless Steel
S - Direct Spark
serial number designations
S 3 0 0 1
SERIAL NUMBER
SPO MODEL
MOTOR SUPPLIER
05 - Universal
18 - Franklin
15 - Marathon
38 - A.O. Smith
replacement parts
When requesting parts please contact your local representative. Please have full model and serial number available. If you require
assistance in locating your representative, please call the number located on the back page.
figure 22.1 - Common replacement parts
model
power
limit Control
size
exhauster
switch
S 3 0 0 1
Hd 30
5H75038
5H75769-1
NUMÉRO DE
Hd 45
5H75038
5H75769-1
SÉRIE
Hd 60
5H75038
5H75769-2
HdB 60
5H75038
5H75769-4
SPO Modèle
Hd 75
5H75038
5H75769-2
HdB 75
5H75038
MOTEUR FOURNISSEUR
5H75769-2
05 - Universal
18 - Franklin
Hd 100
5H79795
5H75769-2
15 - Marathon
38 - A.O. Smith
HdB 100
5H79795
5H75769-3
Hd 125
5H79795
5H75769-1
HdB 125
5H79795
5H75769-2
(Remove access cover to locate)
45
A
S
01
11
Ignition Type
Power Code
01 - 115 volt, 60 hertz,
single phase
(Remove access cover to locate)
CONTROL SUPPLIER
01 - RobertShaw
09 - White Rogers
05 - Honeywell
17 - United Tech
08 - Fenwal
0 0
1 7 9
UNIT SERIES
00 - Original
01 - Modified
FAN VENDOR CODE
20 - Morrison
01 - Revcor
10 - Lau
08 - Brookside
19 - Air Drive
(The list is subject to change. Please refer to unit mounted parts list for most up-to-date list.)
FOURNISSEUR DU RÉGULATEUR
01 - RobertShaw
flame
09 - White Rogers
Trans-
pressure
05 - Honeywell
17 - United Tech
roll-out
former
switch
08 - Fenwal
switch
0 0
1 7 9
5H75002-7
5H75029
5H75030-3
5H75002-7
5H75029
5H75030-3
5H75002-7
5H75029
5H75030-3
5H75002-7
5H75029
5H75030-3
CONFIGURATION
00 - Original
01 - Modifié
5H75002-7
5H75029
5H75030-4
5H75002-7
5H75029
5H75030-4
CODE DU FOURNISSEUR
5H75002-4
5H75029
5H79441-9
VENTILATEUR
5H75002-4
5H75029
5H79441-9
20 - Morrison
01 - Revcor
5H75002-4
5H75029
5H79441-9
10 - Lau
08 - Brookside
5H75002-4
5H75029
5H79441-9
19 - Air Drive
S
B
A
N
Factory Installed Option Digit
N - None
Future
A - All
Dev Digit
Fan Guard Digit
N - None (all blower models)
F - Fingerproof
Control Code
11 - Single Stage, Natural Gas
12 - Two Stage, Natural Gas
21 - Single Stage, Propane Gas
22 - Two Stage, Propane Gas
GAS VALVE SUPPLIER
01 - RobertShaw
05 - Honeywell
09 - White Rogers
YEAR OF MANUFACTURE
0
1
0
9 8
WEEK OF
MANUFACTURE
Same as Requirements
Planning Shop Calendar
FOURNISSEUR DE
ROBINET DE GAZ
01 - RobertShaw
Ignition
05 - Honeywell
Igniter
Control
09 - White Rogers
ANÉE DE FABRICATION
(1 stage)
Code 11
0
1
0
9 8
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
SEMAINE DE
5H79636
5H79749
5H79751
FABRICATION
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
5H79636
5H79749
5H79751
6-583.6
SPO NUMBER
1
2 3 4
1
0 0 0 0
SEQUENTIAL NUMBER
Number varies from 0000 to 9999.
Each unit within same week of
manufacture is to have unique number.
Combination gas
Ignition
valve (1 stage)
Control
SPO NUMÉRO
(2 stage)
Code 21
1
2 3 4
1
0 0 0 0
5H79869
NA
5H79869
NA
5H79869
NA
5H79869
NA
NUMÉRO SÉQUENTIAL
5H79869
5H79804
Number varies from 0000 to 9999.
5H79869
5H79804
5H79869
5H79804
5H79869
5H79804
5H79869
5H79804
5H79869
5H79804
Combination gas
valve (2 stage)
Code 22
Code 12
NA
NA
NA
NA
NA
NA
NA
NA
5H79748
5H79871
5H79748
5H79871
5H79748
5H79871
5H79748
5H79871
5H79748
5H79871
5H79748
5H79871
19

Hide quick links:

Advertisement

Table of Contents
loading