Nokia RM-598 Service Manual page 24

Mobile terminal
Table of Contents

Advertisement

Number of Tx power levels
Environmental conditions
Temperature conditions
Environmental condition
Normal operation
Reduced performance
Intermittent operation
No operation or storage
Charging allowed
Long term storage conditions
Humidity
Relative humidity range is 5...95%.
The HW module is not protected against water. Condensed or splashed water might cause malfunction. Any
submerge of the phone will cause permanent damage. Long-term high humidity, with condensation, will
cause permanent damage because of corrosion.
Vibration
The module should withstand the following vibrations:
• 5 - 10 Hz; +10dB / octave
• 10 - 50 Hz; 5.58 m
2
• 50 - 300 Hz; - 10 dB / octave
ESD strength
Conducted discharge is 8 kV (>10 discharges) and air contact 15 kV ( >10 discharges ).
The standard for electrostatic discharge is IEC 61000-4-2, and this device fulfils level 4 requirements.
Page 1 –12
Parameter
Ambient temperature
o
-10
C...+55
o
-30
C...-10
o
+55
C...+70
o
-40
C...-30
o
+70
C...+85
o
<-40
o
-25
C...+50
o
0
C...+85
3
2
/ s
(0.0558 g
/ Hz)
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
GSM850: 15
GSM900: 15
GSM1800: 16
GSM1900: 16
WCDMA VIII (900): 75
WCDMA V (850): 75
WCDMA II (1900): 75
WCDMA I (2100): 75
o
C
o
C
o
C
o
C
o
C
o
C...>+85
C
o
C
o
C
RM-598; RM-604
General information
Unit
Notes
Specifications fulfilled
Operational for shorts periods
only
Operation not guaranteed but an
attempt to operate does not
damage the phone.
No storage or operation: an
attempt may damage the phone.
Issue 1

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

L4Rm-6047230L3

Table of Contents