Nokia RM-598 Service Manual page 85

Mobile terminal
Table of Contents

Advertisement

RM-598; RM-604
BB Troubleshooting and Manual Tuning Guide
Measurement data
Figure 10 Single-ended output waveform of the Ext_in_HP_out measurement when earpiece is connected.
If a special low-pass filter designed for measuring digital amplifiers is unavailable, the measurement must be performed with a
current probe and the input signal frequency must be 2kHz.
Figure 11 Differential output waveform of the Ext_in_IHF_out out loop measurement when speaker is connected.
Issue 1
COMPANY CONFIDENTIAL
Page 3 –39