Normal And Extreme Voltages; Power Key And System Power-Up - Nokia RM-598 Service Manual

Mobile terminal
Table of Contents

Advertisement

RM-598; RM-604
System Module
• VBAT (Battery voltage)
The BSI line is used to recognize the battery capacity by a battery internal pull down resistor.
Charging
This phone is charged through a separate charger connector.
Charging is controlled by energy management, and external components are needed to protect the baseband
module against EMC, reverse polarity and transient frequency deviation.
Complementary USB charging is supported as well, in case the phone is connected to a PC or to a dedicated
USB charger.

Normal and extreme voltages

Energy management is mainly carried out in the ASIC PEARL/GAZOO. These circuits contain a number of
regulators. In addition there are some external regulators.
In the table below normal and extreme voltages are shown when a BL-4CT battery is used.
Voltage
Nominal voltage
Lower extreme voltage
Higher extreme voltage (fast
charging)
Vmstr+
Vmstr-
Sw shutdown
Sw shutdown
Vcoff+
Vcoff-

Power key and system power-up

When the battery is placed in the phone the power key circuits are energized. When the power key is pressed,
the system boots up (if an adequate battery voltage is present).
Power down can be initiated by pressing the power key again (the system is powered down with the aid of
SW). The power key is connected to EM ASIC N2200 (Gazoo/Pearl) via PWRONX signal.
Issue 1
Table 13 Nominal voltages
Voltage [V]
General Conditions
4.1
3.5
4.2
HW Shutdown Voltages
2.1 ± 0.1
1.9 ± 0.1
SW Shutdown Voltages
3.106
3.2
Min Operating Voltage
2.9 ± 0.1
2.7 ± 0.1
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Condition
Off to on
On to off
In call
In idle
Off to on
On to off
Page 5 –9